Merge "Improve iDrac Documentation"
This commit is contained in:
commit
b462ca420b
@ -5,55 +5,573 @@ iDRAC driver
|
||||
Overview
|
||||
========
|
||||
|
||||
iDRAC_ hardware is supported by the ``idrac`` hardware type. It is also
|
||||
supported by the standard ``ipmi`` hardware type, though with a smaller
|
||||
feature set.
|
||||
The integrated Dell Remote Access Controller (iDRAC_) is an out-of-band
|
||||
management platform on Dell EMC servers, and is supported directly by
|
||||
the ``idrac`` hardware type. This driver uses the Dell Web Services for
|
||||
Management (WSMAN) protocol and the standard Distributed Management Task
|
||||
Force (DMTF) Redfish protocol to perform all of its functions.
|
||||
|
||||
.. TODO(dtantsur): supported hardware
|
||||
iDRAC_ hardware is also supported by the generic ``ipmi`` and ``redfish``
|
||||
hardware types, though with smaller feature sets.
|
||||
|
||||
Key features of the Dell iDRAC driver include:
|
||||
|
||||
* Out-of-band node inspection
|
||||
* Boot device management
|
||||
* Power management
|
||||
* RAID controller management and RAID volume configuration
|
||||
* BIOS settings configuration
|
||||
|
||||
Ironic Features
|
||||
---------------
|
||||
|
||||
The ``idrac`` hardware type supports the following Ironic interfaces:
|
||||
|
||||
* `Inspect Interface`_: Hardware inspection
|
||||
* Management Interface: Boot device management
|
||||
* Power Interface: Power management
|
||||
* `RAID Interface`_: RAID controller and disk management
|
||||
* `Vendor Interface`_: BIOS management
|
||||
|
||||
Prerequisites
|
||||
-------------
|
||||
|
||||
The ``idrac`` hardware type requires the ``python-dracclient`` library
|
||||
to be installed on the ironic conductor node(s) if an Ironic node is
|
||||
configured to use an ``idrac-wsman`` interface implementation, for example::
|
||||
|
||||
sudo pip install 'python-dracclient>=3.1.0'
|
||||
|
||||
Additionally, the ``idrac`` hardware type requires the ``sushy`` library
|
||||
to be installed on the ironic conductor node(s) if an Ironic node is
|
||||
configured to use an ``idrac-redfish`` interface implementation, for example::
|
||||
|
||||
sudo pip install 'python-dracclient>=3.1.0' 'sushy>=2.0.0'
|
||||
|
||||
Enabling
|
||||
========
|
||||
--------
|
||||
|
||||
The ``idrac`` hardware type requires the ``python-dracclient`` library to be
|
||||
installed, for example::
|
||||
The iDRAC driver supports WSMAN for the inspect, management, power,
|
||||
raid, and vendor interfaces. In addition, it supports Redfish for
|
||||
the inspect, management, and power interfaces. The iDRAC driver
|
||||
allows you to mix and match WSMAN and Redfish interfaces.
|
||||
|
||||
sudo pip install 'python-dracclient>=1.5.0,<3.0.0'
|
||||
The ``idrac-wsman`` implementation must be enabled to use WSMAN for
|
||||
an interface. The ``idrac-redfish`` implementation must be enabled
|
||||
to use Redfish for an interface.
|
||||
|
||||
To enable the ``idrac`` hardware type, add the following to your
|
||||
``/etc/ironic/ironic.conf``:
|
||||
.. NOTE::
|
||||
Redfish is supported for only the inspect, management, and power
|
||||
interfaces at the present time.
|
||||
|
||||
To enable the ``idrac`` hardware type with the minimum interfaces,
|
||||
all using WSMAN, add the following to your ``/etc/ironic/ironic.conf``:
|
||||
|
||||
.. code-block:: ini
|
||||
|
||||
[DEFAULT]
|
||||
enabled_hardware_types=idrac-wsman
|
||||
enabled_management_interfaces=idrac-wsman
|
||||
enabled_power_interfaces=idrac-wsman
|
||||
|
||||
To enable all optional features (inspection, RAID, and vendor passthru)
|
||||
using Redfish where it is supported and WSMAN where not, use the
|
||||
following configuration:
|
||||
|
||||
.. code-block:: ini
|
||||
|
||||
[DEFAULT]
|
||||
enabled_hardware_types=idrac
|
||||
enabled_management_interfaces=idrac
|
||||
enabled_power_interfaces=idrac
|
||||
enabled_inspect_interfaces=idrac-redfish
|
||||
enabled_management_interfaces=idrac-redfish
|
||||
enabled_power_interfaces=idrac-redfish
|
||||
enabled_raid_interfaces=idrac-wsman
|
||||
enabled_vendor_interfaces=idrac-wsman
|
||||
|
||||
To enable all optional features (inspection, RAID and vendor passthru), use
|
||||
the following configuration:
|
||||
Below is the list of supported interface implementations in priority
|
||||
order:
|
||||
|
||||
.. code-block:: ini
|
||||
================ ===================================================
|
||||
Interface Supported Implementations
|
||||
================ ===================================================
|
||||
``bios`` ``no-bios``
|
||||
``boot`` ``ipxe``, ``pxe``
|
||||
``console`` ``no-console``
|
||||
``deploy`` ``iscsi``, ``direct``, ``ansible``, ``ramdisk``
|
||||
``inspect`` ``idrac-wsman``, ``idrac``, ``idrac-redfish``,
|
||||
``inspector``, ``no-inspect``
|
||||
``management`` ``idrac-wsman``, ``idrac``, ``idrac-redfish``
|
||||
``network`` ``flat``, ``neutron``, ``noop``
|
||||
``power`` ``idrac-wsman``, ``idrac``, ``idrac-redfish``
|
||||
``raid`` ``idrac-wsman``, ``idrac``, ``no-raid``
|
||||
``rescue`` ``no-rescue``, ``agent``
|
||||
``storage`` ``noop``, ``cinder``, ``external``
|
||||
``vendor`` ``idrac-wsman``, ``idrac``, ``no-vendor``
|
||||
================ ===================================================
|
||||
|
||||
[DEFAULT]
|
||||
enabled_hardware_types=idrac
|
||||
enabled_inspect_interfaces=idrac
|
||||
enabled_management_interfaces=idrac
|
||||
enabled_power_interfaces=idrac
|
||||
enabled_raid_interfaces=idrac
|
||||
enabled_vendor_interfaces=idrac
|
||||
.. NOTE::
|
||||
``idrac`` is the legacy name of the WSMAN interface. It has been
|
||||
deprecated in favor of ``idrac-wsman`` and may be removed in a
|
||||
future release.
|
||||
|
||||
Protocol-specific Properties
|
||||
----------------------------
|
||||
|
||||
The WSMAN and Redfish protocols require different properties to be specified
|
||||
in the Ironic node's ``driver_info`` field to communicate with the bare
|
||||
metal system's iDRAC.
|
||||
|
||||
The WSMAN protocol requires the following properties:
|
||||
|
||||
* ``drac_username``: The WSMAN user name to use when communicating
|
||||
with the iDRAC. Usually ``root``.
|
||||
* ``drac_password``: The password for the WSMAN user to use when
|
||||
communicating with the iDRAC.
|
||||
* ``drac_address``: The IP address of the iDRAC.
|
||||
|
||||
The Redfish protocol requires the following properties:
|
||||
|
||||
* ``redfish_username``: The Redfish user name to use when
|
||||
communicating with the iDRAC. Usually ``root``.
|
||||
* ``redfish_password``: The password for the Redfish user to use
|
||||
when communicating with the iDRAC.
|
||||
* ``redfish_address``: The URL address of the iDRAC. It must include the
|
||||
authority portion of the URL, and can optionally include the scheme. If
|
||||
the scheme is missing, https is assumed.
|
||||
* ``redfish_system_id``: The Redfish ID of the server to be
|
||||
managed. This should always be: ``/redfish/v1/Systems/System.Embedded.1``.
|
||||
|
||||
If using only interfaces which use WSMAN (``idrac-wsman``), then only
|
||||
the WSMAN properties must be supplied. If using only interfaces which
|
||||
use Redfish (``idrac-redfish``), then only the Redfish properties must be
|
||||
supplied. If using a mix of interfaces, where some use WSMAN and others
|
||||
use Redfish, both the WSMAN and Redfish properties must be supplied.
|
||||
|
||||
Enrolling
|
||||
=========
|
||||
---------
|
||||
|
||||
The following command will enroll a bare metal node with the ``idrac``
|
||||
hardware type::
|
||||
The following command enrolls a bare metal node with the ``idrac``
|
||||
hardware type using WSMAN for all interfaces:
|
||||
|
||||
.. code-block:: bash
|
||||
|
||||
openstack baremetal node create --driver idrac \
|
||||
--driver-info drac_username=user \
|
||||
--driver-info drac_password=pa$$w0rd \
|
||||
--driver-info drac_address=drac.host
|
||||
|
||||
The following command enrolls a bare metal node with the ``idrac``
|
||||
hardware type using Redfish for all interfaces:
|
||||
|
||||
.. code-block:: bash
|
||||
|
||||
openstack baremetal node create --driver idrac \
|
||||
--driver-info redfish_username=user \
|
||||
--driver-info redfish_password=pa$$w0rd \
|
||||
--driver-info redfish_address=drac.host \
|
||||
--driver-info redfish_system_id=/redfish/v1/Systems/System.Embedded.1 \
|
||||
--inspect-interface idrac-redfish \
|
||||
--management-interface idrac-redfish \
|
||||
--power-interface idrac-redfish \
|
||||
--raid-interface no-raid \
|
||||
--vendor-interface no-vendor
|
||||
|
||||
The following command enrolls a bare metal node with the ``idrac``
|
||||
hardware type assuming a mix of Redfish and WSMAN interfaces are used:
|
||||
|
||||
.. code-block:: bash
|
||||
|
||||
openstack baremetal node create --driver idrac \
|
||||
--driver-info drac_address=drac.host \
|
||||
--driver-info drac_username=user \
|
||||
--driver-info drac_password=pa$$w0rd
|
||||
--driver-info drac_address=drac.host \
|
||||
--driver-info redfish_username=user \
|
||||
--driver-info redfish_password=pa$$w0rd \
|
||||
--driver-info redfish_address=drac.host \
|
||||
--driver-info redfish_system_id=/redfish/v1/Systems/System.Embedded.1 \
|
||||
--inspect-interface idrac-redfish \
|
||||
--management-interface idrac-redfish \
|
||||
--power-interface idrac-redfish
|
||||
|
||||
.. TODO(dtantsur): describe RAID support and inspection
|
||||
.. NOTE::
|
||||
If using WSMAN for the management interface, then WSMAN must be used
|
||||
for the power interface. The same applies to Redfish. It is currently not
|
||||
possible to use Redfish for one and WSMAN for the other.
|
||||
|
||||
Inspect Interface
|
||||
=================
|
||||
|
||||
The Dell iDRAC out-of-band inspection process catalogs all the same
|
||||
attributes of the server as the IPMI driver. Unlike IPMI, it does this
|
||||
without requiring the system to be rebooted, or even to be powered on.
|
||||
Inspection is performed using the Dell WSMAN or Redfish protocol directly
|
||||
without affecting the operation of the system being inspected.
|
||||
|
||||
The inspection discovers the following properties:
|
||||
|
||||
* ``cpu_arch``: cpu architecture
|
||||
* ``cpus``: number of cpus
|
||||
* ``local_gb``: disk size in gigabytes
|
||||
* ``memory_mb``: memory size in megabytes
|
||||
|
||||
Extra capabilities:
|
||||
|
||||
* ``boot_mode``: UEFI or BIOS boot mode.
|
||||
|
||||
It also creates baremetal ports for each NIC port detected in the system.
|
||||
The ``idrac-wsman`` inspect interface discovers which NIC ports are
|
||||
configured to PXE boot and sets ``pxe_enabled`` to ``True`` on those ports.
|
||||
The ``idrac-redfish`` inspect interface does not currently set ``pxe_enabled``
|
||||
on the ports. The user should ensure that ``pxe_enabled`` is set correctly on
|
||||
the ports following inspection with the ``idrac-redfish`` inspect interface.
|
||||
|
||||
|
||||
RAID Interface
|
||||
==============
|
||||
|
||||
See :doc:`/admin/raid` for more information on Ironic RAID support.
|
||||
|
||||
The following properties are supported by the iDRAC WSMAN raid interface
|
||||
implementation, ``idrac-wsman``:
|
||||
|
||||
|
||||
Mandatory properties
|
||||
--------------------
|
||||
|
||||
* ``size_gb``: Size in gigabytes (integer) for the logical disk. Use ``MAX`` as
|
||||
``size_gb`` if this logical disk is supposed to use the rest of the space available.
|
||||
* ``raid_level``: RAID level for the logical disk. Valid values are
|
||||
``0``, ``1``, ``5``, ``6``, ``1+0``, ``5+0`` and ``6+0``.
|
||||
|
||||
.. NOTE::
|
||||
``JBOD`` and ``2`` are not supported, and will fail with reason: 'Cannot
|
||||
calculate spans for RAID level.'
|
||||
|
||||
Optional properties
|
||||
-------------------
|
||||
|
||||
* ``is_root_volume``: Optional. Specifies whether this disk is a root volume.
|
||||
By default, this is ``False``.
|
||||
* ``volume_name``: Optional. Name of the volume to be created. If this is not
|
||||
specified, it will be auto-generated.
|
||||
|
||||
Backing physical disk hints
|
||||
---------------------------
|
||||
|
||||
See :doc:`/admin/raid` for more information on backing disk hints.
|
||||
|
||||
These are machine-independent information. The hints are specified for each
|
||||
logical disk to help Ironic find the desired disks for RAID configuration.
|
||||
|
||||
* ``disk_type``
|
||||
* ``interface_type``
|
||||
* ``share_physical_disks``
|
||||
* ``number_of_physical_disks``
|
||||
|
||||
Backing physical disks
|
||||
----------------------
|
||||
|
||||
These are Dell RAID controller-specific values and must match the
|
||||
names provided by the iDRAC.
|
||||
|
||||
* ``controller``: Mandatory. The name of the controller to use.
|
||||
* ``physical_disks``: Optional. The names of the physical disks to use.
|
||||
|
||||
.. NOTE::
|
||||
``physical_disks`` is a mandatory parameter if the property ``size_gb`` is set to ``MAX``.
|
||||
|
||||
Examples
|
||||
--------
|
||||
|
||||
Creation of RAID ``1+0`` logical disk with six disks on one controller:
|
||||
|
||||
.. code-block:: json
|
||||
|
||||
{ "logical_disks":
|
||||
[ { "controller": "RAID.Integrated.1-1",
|
||||
"is_root_volume": "True",
|
||||
"physical_disks": [
|
||||
"Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1",
|
||||
"Disk.Bay.1:Enclosure.Internal.0-1:RAID.Integrated.1-1",
|
||||
"Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1",
|
||||
"Disk.Bay.3:Enclosure.Internal.0-1:RAID.Integrated.1-1",
|
||||
"Disk.Bay.4:Enclosure.Internal.0-1:RAID.Integrated.1-1",
|
||||
"Disk.Bay.5:Enclosure.Internal.0-1:RAID.Integrated.1-1"],
|
||||
"raid_level": "1+0",
|
||||
"size_gb": "MAX"}]}
|
||||
|
||||
|
||||
Manual RAID Invocation
|
||||
----------------------
|
||||
|
||||
The following command can be used to delete any existing RAID configuration.
|
||||
It deletes all virtual disks/RAID volumes, unassigns all global and dedicated
|
||||
hot spare physical disks, and clears foreign configuration:
|
||||
|
||||
.. code-block:: bash
|
||||
|
||||
openstack baremetal node clean --clean-steps \
|
||||
'[{"interface": "raid", "step": "delete_configuration"}]' ${node_uuid}
|
||||
|
||||
|
||||
The following command shows an example of how to set the target RAID
|
||||
configuration:
|
||||
|
||||
.. code-block:: bash
|
||||
|
||||
openstack baremetal node set --target-raid-config '{ "logical_disks":
|
||||
[ { "controller": "RAID.Integrated.1-1",
|
||||
"is_root_volume": true,
|
||||
"physical_disks": [
|
||||
"Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1",
|
||||
"Disk.Bay.1:Enclosure.Internal.0-1:RAID.Integrated.1-1"],
|
||||
"raid_level": "0",
|
||||
"size_gb": "MAX"}]}' ${node_uuid}
|
||||
|
||||
|
||||
The following command can be used to create a RAID configuration:
|
||||
|
||||
.. code-block:: bash
|
||||
|
||||
openstack baremetal node clean --clean-steps \
|
||||
'[{"interface": "raid", "step": "create_configuration"}]' ${node_uuid}
|
||||
|
||||
|
||||
When the physical disk names or controller names are not known, the
|
||||
following Python code example shows how the ``python-dracclient`` can
|
||||
be used to fetch the information directly from the Dell bare metal:
|
||||
|
||||
.. code-block:: python
|
||||
|
||||
import dracclient.client
|
||||
|
||||
|
||||
client = dracclient.client.DRACClient(
|
||||
host="192.168.1.1",
|
||||
username="root",
|
||||
password="calvin")
|
||||
controllers = client.list_raid_controllers()
|
||||
print(controllers)
|
||||
|
||||
physical_disks = client.list_physical_disks()
|
||||
print(physical_disks)
|
||||
|
||||
|
||||
Vendor Interface
|
||||
================
|
||||
|
||||
Dell iDRAC BIOS management is available through the Ironic vendor
|
||||
passthru interface.
|
||||
|
||||
======================== ============ ======================================
|
||||
Method Name HTTP Method Description
|
||||
======================== ============ ======================================
|
||||
``abandon_bios_config`` ``DELETE`` Abandon a BIOS configuration job.
|
||||
``commit_bios_config`` ``POST`` Commit a BIOS configuration job
|
||||
submitted through ``set_bios_config``.
|
||||
Required argument: ``reboot`` -
|
||||
indicates whether a reboot job
|
||||
should be automatically created
|
||||
with the config job. Returns a
|
||||
dictionary containing the ``job_id``
|
||||
key with the ID of the newly created
|
||||
config job, and the
|
||||
``reboot_required`` key indicating
|
||||
whether the node needs to be rebooted
|
||||
to execute the config job.
|
||||
``get_bios_config`` ``GET`` Returns a dictionary containing the
|
||||
node's BIOS settings.
|
||||
``list_unfinished_jobs`` ``GET`` Returns a dictionary containing
|
||||
the key ``unfinished_jobs``; its value
|
||||
is a list of dictionaries. Each
|
||||
dictionary represents an unfinished
|
||||
config job object.
|
||||
``set_bios_config`` ``POST`` Change the BIOS configuration on
|
||||
a node. Required argument: a
|
||||
dictionary of {``AttributeName``:
|
||||
``NewValue``}. Returns a dictionary
|
||||
containing the ``is_commit_required``
|
||||
key indicating whether
|
||||
``commit_bios_config`` needs to be
|
||||
called to apply the changes and the
|
||||
``is_reboot_required`` value
|
||||
indicating whether the server must
|
||||
also be rebooted. Possible values are
|
||||
``true`` and ``false``.
|
||||
======================== ============ ======================================
|
||||
|
||||
|
||||
Examples
|
||||
--------
|
||||
|
||||
Get BIOS Config
|
||||
~~~~~~~~~~~~~~~
|
||||
|
||||
.. code-block:: bash
|
||||
|
||||
openstack baremetal node passthru call --http-method GET ${node_uuid} get_bios_config
|
||||
|
||||
Snippet of output showing virtualization enabled:
|
||||
|
||||
.. code-block:: json
|
||||
|
||||
{"ProcVirtualization": {
|
||||
"current_value": "Enabled",
|
||||
"instance_id": "BIOS.Setup.1-1:ProcVirtualization",
|
||||
"name": "ProcVirtualization",
|
||||
"pending_value": null,
|
||||
"possible_values": [
|
||||
"Enabled",
|
||||
"Disabled"],
|
||||
"read_only": false }}
|
||||
|
||||
There are a number of items to note from the above snippet:
|
||||
|
||||
* ``name``: this is the name to use in a call to ``set_bios_config``.
|
||||
* ``current_value``: the current state of the setting.
|
||||
* ``pending_value``: if the value has been set, but not yet committed,
|
||||
the new value is shown here. The change can either be committed or
|
||||
abandoned.
|
||||
* ``possible_values``: shows a list of valid values which can be used
|
||||
in a call to ``set_bios_config``.
|
||||
* ``read_only``: indicates if the value is capable of being changed.
|
||||
|
||||
Set BIOS Config
|
||||
~~~~~~~~~~~~~~~
|
||||
|
||||
.. code-block:: bash
|
||||
|
||||
openstack baremetal node passthru call ${node_uuid} set_bios_config --arg "name=value"
|
||||
|
||||
|
||||
Walkthrough of perfoming a BIOS configuration change:
|
||||
|
||||
The following section demonstrates how to change BIOS configuration settings,
|
||||
detect that a commit and reboot are required, and act on them accordingly. The
|
||||
two properties that are being changed are:
|
||||
|
||||
* Enable virtualization technology of the processor
|
||||
* Globally enable SR-IOV
|
||||
|
||||
.. code-block:: bash
|
||||
|
||||
openstack baremetal node passthru call ${node_uuid} set_bios_config \
|
||||
--arg "ProcVirtualization=Enabled" \
|
||||
--arg "SriovGlobalEnable=Enabled"
|
||||
|
||||
This returns a dictionary indicating what actions are required next:
|
||||
|
||||
.. code-block:: json
|
||||
|
||||
{
|
||||
"is_reboot_required": true,
|
||||
"is_commit_required": true
|
||||
}
|
||||
|
||||
|
||||
Commit BIOS Changes
|
||||
~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
The next step is to commit the pending change to the BIOS. Note that in this
|
||||
example, the ``reboot`` argument is set to ``true``. The response indicates
|
||||
that a reboot is no longer required as it has been scheduled automatically
|
||||
by the ``commit_bios_config`` call. If the reboot argument is not supplied,
|
||||
the job is still created, however it remains in the ``scheduled`` state
|
||||
until a reboot is performed. The reboot can be initiated through the
|
||||
Ironic power API.
|
||||
|
||||
.. code-block:: bash
|
||||
|
||||
openstack baremetal node passthru call ${node_uuid} commit_bios_config \
|
||||
--arg "reboot=true"
|
||||
|
||||
.. code-block:: json
|
||||
|
||||
{
|
||||
"job_id": "JID_499377293428",
|
||||
"reboot_required": false
|
||||
}
|
||||
|
||||
The state of any executing job can be queried:
|
||||
|
||||
.. code-block:: bash
|
||||
|
||||
openstack baremetal node passthru call --http-method GET ${node_uuid} list_unfinished_jobs
|
||||
|
||||
|
||||
.. code-block:: json
|
||||
|
||||
{"unfinished_jobs":
|
||||
[{"status": "Scheduled",
|
||||
"name": "ConfigBIOS:BIOS.Setup.1-1",
|
||||
"until_time": "TIME_NA",
|
||||
"start_time": "TIME_NOW",
|
||||
"message": "Task successfully scheduled.",
|
||||
"percent_complete": "0",
|
||||
"id": "JID_499377293428"}]}
|
||||
|
||||
|
||||
Abandon BIOS Changes
|
||||
~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
Instead of committing, a pending change can be abandoned:
|
||||
|
||||
.. code-block:: bash
|
||||
|
||||
openstack baremetal node passthru call --http-method DELETE ${node_uuid} abandon_bios_config
|
||||
|
||||
The abandon command does not provide a response body.
|
||||
|
||||
|
||||
Change Boot Mode
|
||||
----------------
|
||||
|
||||
The boot mode of the iDRAC can be changed to:
|
||||
|
||||
* BIOS - Also called legacy or traditional boot mode. The BIOS initializes the
|
||||
system’s processors, memory, bus controllers, and I/O devices. After
|
||||
initialization is complete, the BIOS passes control to operating system (OS)
|
||||
software. The OS loader uses basic services provided by the system BIOS to
|
||||
locate and load OS modules into system memory. After booting the system, the
|
||||
BIOS and embedded management controllers execute system management
|
||||
algorithms, which monitor and optimize the condition of the underlying
|
||||
hardware. BIOS configuration settings enable fine-tuning of the
|
||||
performance, power management, and reliability features of the system.
|
||||
* UEFI - The Unified Extensible Firmware Interface does not change the
|
||||
traditional purposes of the system BIOS. To a large extent, a UEFI-compliant
|
||||
BIOS performs the same initialization, boot, configuration, and management
|
||||
tasks as a traditional BIOS. However, UEFI does change the interfaces and
|
||||
data structures the BIOS uses to interact with I/O device firmware and
|
||||
operating system software. The primary intent of UEFI is to eliminate
|
||||
shortcomings in the traditional BIOS environment, enabling system firmware to
|
||||
continue scaling with industry trends.
|
||||
|
||||
The UEFI boot mode offers:
|
||||
|
||||
* Improved partitioning scheme for boot media
|
||||
* Support for media larger than 2 TB
|
||||
* Redundant partition tables
|
||||
* Flexible handoff from BIOS to OS
|
||||
* Consolidated firmware user interface
|
||||
* Enhanced resource allocation for boot device firmware
|
||||
|
||||
The boot mode can be changed via the vendor passthru interface as follows:
|
||||
|
||||
.. code-block:: bash
|
||||
|
||||
openstack baremetal node passthru call ${node_uuid} set_bios_config \
|
||||
--arg "BootMode=Uefi"
|
||||
|
||||
openstack baremetal node passthru call ${node_uuid} commit_bios_config \
|
||||
--arg "reboot=true"
|
||||
|
||||
.. code-block:: bash
|
||||
|
||||
openstack baremetal node passthru call ${node_uuid} set_bios_config \
|
||||
--arg "BootMode=Bios"
|
||||
|
||||
openstack baremetal node passthru call ${node_uuid} commit_bios_config \
|
||||
--arg "reboot=true"
|
||||
|
||||
Known Issues
|
||||
============
|
||||
@ -66,4 +584,5 @@ into maintenance mode in Ironic. This issue can be worked around by changing
|
||||
the Ironic power state poll interval to 70 seconds. See
|
||||
``[conductor]sync_power_state_interval`` in ``/etc/ironic/ironic.conf``.
|
||||
|
||||
.. _iDRAC: https://www.dell.com/support/manuals/us/en/15/openmanage-software-9.0.1/om_9.0.1_support_matrix/supported-integrated-dell-remote-access-controllers-and-solutions?guid=guid-07259e0b-a788-4a78-8f40-d46ef06a7697&lang=en-us
|
||||
.. _Ironic_RAID: https://docs.openstack.org/ironic/latest/admin/raid.html
|
||||
.. _iDRAC: https://www.dell.com/idracmanuals
|
||||
|