Fast-Track Deployment
=====================
*Fast track* is a mode of operation where the Bare Metal service keeps a
machine powered on with the agent running between provisioning operations.
It is first booted during in-band inspection or cleaning (whatever happens
first) and is only shut down before rebooting into the final instance.
Depending on the configuration, this mode can save several reboots and is
particularly useful for scenarios where nodes are enrolled, prepared and
provisioned within a short time.
.. warning::
Fast track deployment targets standalone use cases and is only tested with
the ``noop`` networking. The case where inspection, cleaning, and
provisioning networks are different is not supported.
.. note::
Fast track mode is very sensitive to long-running processes on the conductor
side that may prevent agent heartbeats from being registered.
For example, converting a large image to the raw format may take long enough
to reach the fast-track timeout. In this case, you can either :ref:`use raw
images <stream_raw_images>` or move the conversion to the agent side with:
.. code-block:: ini
[DEFAULT]
force_raw_images = False
Enabling
========
Fast track is off by default and should be enabled in the configuration:
.. code-block:: ini
[deploy]
fast_track = true
Starting with the Yoga release series, it can also be enabled or disabled per
node:
.. code-block:: console
baremetal node set <node> --driver-info fast_track=true
Inspection
----------
If using :ref:`in-band inspection`, you need to tell ironic or ironic-inspector
not to power off nodes afterwards. Depending on the inspection mode (managed or
unmanaged, with ironic-inspector or without), you need to configure two places.
In ``ironic.conf``:
.. code-block:: ini
[inspector]
power_off = false
And in ``inspector.conf`` (if needed):
.. code-block:: ini
[processing]
power_off = false
Finally, you need to update the :ref:`inspection PXE/iPXE
configuration <configure-unmanaged-inspection>` to include the
``ipa-api-url`` kernel parameter, pointing at the **ironic** endpoint, in
addition to the existing ``ipa-inspection-callback-url``.