The iSCSI deploy was very easy to start with, but it has since become apparently that it suffers from scalability and maintenance issues. It was deprecated in the Victoria cycle and can now be removed. Hide the guide to upgrade to hardware types since it's very outdated. I had to remove the iBMC diagram since my SVG-fu is not enough to fix it. Change-Id: I2cd6bf7b27fe0be2c08104b0cc37654b506b2e62
318 lines
10 KiB
ReStructuredText
318 lines
10 KiB
ReStructuredText
===============
|
|
iBMC driver
|
|
===============
|
|
|
|
Overview
|
|
========
|
|
|
|
The ``ibmc`` driver is targeted for Huawei V5 series rack server such as
|
|
2288H V5, CH121 V5. The iBMC hardware type enables the user to take advantage
|
|
of features of `Huawei iBMC`_ to control Huawei server.
|
|
|
|
The ``ibmc`` hardware type supports the following Ironic interfaces:
|
|
|
|
* Management Interface: Boot device management
|
|
* Power Interface: Power management
|
|
* `RAID Interface`_: RAID controller and disk management
|
|
* `Vendor Interface`_: ibmc passthru interfaces
|
|
|
|
Prerequisites
|
|
=============
|
|
|
|
The `HUAWEI iBMC Client library`_ should be installed on the ironic conductor
|
|
node(s).
|
|
|
|
For example, it can be installed with ``pip``::
|
|
|
|
sudo pip install python-ibmcclient
|
|
|
|
Enabling the iBMC driver
|
|
============================
|
|
|
|
#. Add ``ibmc`` to the list of ``enabled_hardware_types``,
|
|
``enabled_power_interfaces``, ``enabled_vendor_interfaces``
|
|
and ``enabled_management_interfaces`` in ``/etc/ironic/ironic.conf``. For example::
|
|
|
|
[DEFAULT]
|
|
...
|
|
enabled_hardware_types = ibmc
|
|
enabled_power_interfaces = ibmc
|
|
enabled_management_interfaces = ibmc
|
|
enabled_raid_interfaces = ibmc
|
|
enabled_vendor_interfaces = ibmc
|
|
|
|
#. Restart the ironic conductor service::
|
|
|
|
sudo service ironic-conductor restart
|
|
|
|
# Or, for RDO:
|
|
sudo systemctl restart openstack-ironic-conductor
|
|
|
|
Registering a node with the iBMC driver
|
|
===========================================
|
|
|
|
Nodes configured to use the driver should have the ``driver`` property
|
|
set to ``ibmc``.
|
|
|
|
The following properties are specified in the node's ``driver_info``
|
|
field:
|
|
|
|
- ``ibmc_address``:
|
|
|
|
The URL address to the ibmc controller. It must
|
|
include the authority portion of the URL, and can
|
|
optionally include the scheme. If the scheme is
|
|
missing, https is assumed.
|
|
For example: https://ibmc.example.com. This is required.
|
|
|
|
- ``ibmc_username``:
|
|
|
|
User account with admin/server-profile access
|
|
privilege. This is required.
|
|
|
|
- ``ibmc_password``:
|
|
|
|
User account password. This is required.
|
|
|
|
- ``ibmc_verify_ca``:
|
|
|
|
If ibmc_address has the **https** scheme, the
|
|
driver will use a secure (TLS_) connection when
|
|
talking to the ibmc controller. By default
|
|
(if this is set to True), the driver will try to
|
|
verify the host certificates. This can be set to
|
|
the path of a certificate file or directory with
|
|
trusted certificates that the driver will use for
|
|
verification. To disable verifying TLS_, set this
|
|
to False. This is optional.
|
|
|
|
The ``baremetal node create`` command can be used to enroll
|
|
a node with the ``ibmc`` driver. For example:
|
|
|
|
.. code-block:: bash
|
|
|
|
baremetal node create --driver ibmc
|
|
--driver-info ibmc_address=https://example.com \
|
|
--driver-info ibmc_username=admin \
|
|
--driver-info ibmc_password=password
|
|
|
|
For more information about enrolling nodes see :ref:`enrollment`
|
|
in the install guide.
|
|
|
|
RAID Interface
|
|
==============
|
|
|
|
Currently, only RAID controller which supports OOB management can be managed.
|
|
|
|
See :doc:`/admin/raid` for more information on Ironic RAID support.
|
|
|
|
The following properties are supported by the iBMC raid interface
|
|
implementation, ``ibmc``:
|
|
|
|
Mandatory properties
|
|
--------------------
|
|
|
|
* ``size_gb``: Size in gigabytes (integer) for the logical disk. Use ``MAX`` as
|
|
``size_gb`` if this logical disk is supposed to use the rest of the space
|
|
available.
|
|
* ``raid_level``: RAID level for the logical disk. Valid values are
|
|
``JBOD``, ``0``, ``1``, ``5``, ``6``, ``1+0``, ``5+0`` and ``6+0``. And it
|
|
is possible that some RAID controllers can only support a subset RAID
|
|
levels.
|
|
|
|
.. NOTE::
|
|
RAID level ``2`` is not supported by ``iBMC`` driver.
|
|
|
|
Optional properties
|
|
-------------------
|
|
|
|
* ``is_root_volume``: Optional. Specifies whether this disk is a root volume.
|
|
By default, this is ``False``.
|
|
* ``volume_name``: Optional. Name of the volume to be created. If this is not
|
|
specified, it will be N/A.
|
|
|
|
Backing physical disk hints
|
|
---------------------------
|
|
|
|
See :doc:`/admin/raid` for more information on backing disk hints.
|
|
|
|
These are machine-independent properties. The hints are specified for each
|
|
logical disk to help Ironic find the desired disks for RAID configuration.
|
|
|
|
* ``share_physical_disks``
|
|
* ``disk_type``
|
|
* ``interface_type``
|
|
* ``number_of_physical_disks``
|
|
|
|
Backing physical disks
|
|
----------------------
|
|
|
|
These are HUAWEI RAID controller dependent properties:
|
|
|
|
* ``controller``: Optional. Supported values are: RAID storage id,
|
|
RAID storage name or RAID controller name. If a bare metal server have more
|
|
than one controller, this is mandatory. Typical values would look like:
|
|
|
|
* RAID Storage Id: ``RAIDStorage0``
|
|
* RAID Storage Name: ``RAIDStorage0``
|
|
* RAID Controller Name: ``RAID Card1 Controller``.
|
|
|
|
* ``physical_disks``: Optional. Supported values are: disk-id, disk-name or
|
|
disk serial number. Typical values for hdd disk would look like:
|
|
|
|
* Disk Id: ``HDDPlaneDisk0``
|
|
* Disk Name: ``Disk0``.
|
|
* Disk SerialNumber: ``38DGK77LF77D``
|
|
|
|
Delete RAID configuration
|
|
-------------------------
|
|
|
|
For ``delete_configuration`` step, ``ibmc`` will do:
|
|
|
|
* delete all logical disks
|
|
* delete all hot-spare disks
|
|
|
|
Logical disks creation priority
|
|
-------------------------------
|
|
|
|
Logical Disks creation priority based on three properties:
|
|
|
|
* ``share_physical_disks``
|
|
* ``physical_disks``
|
|
* ``size_gb``
|
|
|
|
The logical disks creation priority strictly follow the table below, if
|
|
multiple logical disks have the same priority, then they will be created with
|
|
the same order in ``logical_disks`` array.
|
|
|
|
==================== ========================== =========
|
|
Share physical disks Specified Physical Disks Size
|
|
==================== ========================== =========
|
|
no yes int|max
|
|
no no int
|
|
yes yes int
|
|
yes yes max
|
|
yes no int
|
|
yes no max
|
|
no no max
|
|
==================== ========================== =========
|
|
|
|
Physical disks choice strategy
|
|
------------------------------
|
|
|
|
.. note::
|
|
physical-disk-group: a group of physical disks which have been used by some
|
|
logical-disks with same RAID level.
|
|
|
|
|
|
* If no ``physical_disks`` are specified, the "waste least" strategy will be
|
|
used to choose the physical disks.
|
|
|
|
* waste least disk capacity: when using disks with different capacity, it
|
|
will cause a waste of disk capacity. This is to avoid with highest
|
|
priority.
|
|
* using least total disk capacity: for example, we can create 400G RAID 5
|
|
with both 5 100G-disks and 3 200G-disks. 5 100G disks is a better
|
|
strategy because it uses a 500G capacity totally. While 3 200G-disks
|
|
are 600G totally.
|
|
* using least disk count: finally, if waste capacity and total disk
|
|
capacity are both the same (it rarely happens?), we will choose the one
|
|
with the minimum number of disks.
|
|
|
|
* when ``share_physical_disks`` option is present, ``ibmc`` driver will
|
|
create logical disk upon existing physical-disk-group list first. Only
|
|
when no existing physical-disk-group matches, then it chooses unused
|
|
physical disks with same strategy described above. When multiple exists
|
|
physical-disk-groups matches, it will use "waste least" strategy too,
|
|
the bigger capacity left the better. For example, to create a logical disk
|
|
shown below on a ``ibmc`` server which has two RAID5 logical disks already.
|
|
And the shareable capacity of this two logical-disks are 500G and 300G,
|
|
then ``ibmc`` driver will choose the second one.
|
|
|
|
.. code-block:: json
|
|
|
|
{
|
|
"logical_disks": [
|
|
{
|
|
"controller": "RAID Card1 Controller",
|
|
"raid_level": "5",
|
|
"size_gb": 100,
|
|
"share_physical_disks": true
|
|
}
|
|
]
|
|
}
|
|
|
|
And the ``ibmc`` server has two RAID5 logical disks already.
|
|
|
|
* When ``size_gb`` is set to ``MAX``, ``ibmc`` driver will auto work through
|
|
all possible cases and choose the "best" solution which has the biggest
|
|
capacity and use least capacity. For example: to create a RAID 5+0 logical
|
|
disk with MAX size in a server has 9 200G-disks, it will finally choose
|
|
"8 disks + span-number 2" but not "9 disks + span-number 3". Although they
|
|
both have 1200G capacity totally, but the former uses only 8 disks and the
|
|
latter uses 9 disks. If you want to choose the latter solution, you can
|
|
specified the disk count to use by adding ``number_of_physical_disks``
|
|
option.
|
|
|
|
.. code-block:: json
|
|
|
|
{
|
|
"logical_disks": [
|
|
{
|
|
"controller": "RAID Card1 Controller",
|
|
"raid_level": "5+0",
|
|
"size_gb": "MAX"
|
|
}
|
|
]
|
|
}
|
|
|
|
|
|
Examples
|
|
--------
|
|
|
|
In a typical scenario we may want to create:
|
|
* RAID 5, 500G, root OS volume with 3 disks
|
|
* RAID 5, rest available space, data volume with rest disks
|
|
|
|
.. code-block:: json
|
|
|
|
{
|
|
"logical_disks": [
|
|
{
|
|
"volume_name": "os_volume",
|
|
"controller": "RAID Card1 Controller",
|
|
"is_root_volume": "True",
|
|
"physical_disks": [
|
|
"Disk0",
|
|
"Disk1",
|
|
"Disk2"
|
|
],
|
|
"raid_level": "5",
|
|
"size_gb": "500"
|
|
},
|
|
{
|
|
"volume_name": "data_volume",
|
|
"controller": "RAID Card1 Controller",
|
|
"raid_level": "5",
|
|
"size_gb": "MAX"
|
|
}
|
|
]
|
|
}
|
|
|
|
Vendor Interface
|
|
=========================================
|
|
|
|
The ``ibmc`` hardware type provides vendor passthru interfaces shown below:
|
|
|
|
|
|
======================== ============ ======================================
|
|
Method Name HTTP Method Description
|
|
======================== ============ ======================================
|
|
boot_up_seq GET Query boot up sequence
|
|
get_raid_controller_list GET Query RAID controller summary info
|
|
======================== ============ ======================================
|
|
|
|
.. _Huawei iBMC: https://e.huawei.com/en/products/cloud-computing-dc/servers/accessories/ibmc
|
|
.. _TLS: https://en.wikipedia.org/wiki/Transport_Layer_Security
|
|
.. _HUAWEI iBMC Client library: https://pypi.org/project/python-ibmcclient/
|