A new option is introduced for that, which defaults to the deploy timeout if it is set and to 1800 seconds if it is not. Change-Id: I10e02919e40d25bd4411f2b6f98f9317d1cfb187 Story: #1653112 Task: #9707
219 lines
11 KiB
Python
219 lines
11 KiB
Python
# Copyright 2016 Intel Corporation
|
|
# Copyright 2013 Hewlett-Packard Development Company, L.P.
|
|
# Copyright 2013 International Business Machines Corporation
|
|
# All Rights Reserved.
|
|
#
|
|
# Licensed under the Apache License, Version 2.0 (the "License"); you may
|
|
# not use this file except in compliance with the License. You may obtain
|
|
# a copy of the License at
|
|
#
|
|
# http://www.apache.org/licenses/LICENSE-2.0
|
|
#
|
|
# Unless required by applicable law or agreed to in writing, software
|
|
# distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
|
|
# WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
|
|
# License for the specific language governing permissions and limitations
|
|
# under the License.
|
|
|
|
from oslo_config import cfg
|
|
|
|
from ironic.common.i18n import _
|
|
|
|
opts = [
|
|
cfg.IntOpt('workers_pool_size',
|
|
default=100, min=3,
|
|
help=_('The size of the workers greenthread pool. '
|
|
'Note that 2 threads will be reserved by the conductor '
|
|
'itself for handling heart beats and periodic tasks. '
|
|
'On top of that, `sync_power_state_workers` will take '
|
|
'up to 7 green threads with the default value of 8.')),
|
|
cfg.IntOpt('heartbeat_interval',
|
|
default=10,
|
|
help=_('Seconds between conductor heart beats.')),
|
|
cfg.URIOpt('api_url',
|
|
schemes=('http', 'https'),
|
|
deprecated_for_removal=True,
|
|
deprecated_reason=_("Use [service_catalog]endpoint_override "
|
|
"option instead if required to use "
|
|
"a specific ironic api address, "
|
|
"for example in noauth mode."),
|
|
help=_('URL of Ironic API service. If not set ironic can '
|
|
'get the current value from the keystone service '
|
|
'catalog. If set, the value must start with either '
|
|
'http:// or https://.')),
|
|
cfg.IntOpt('heartbeat_timeout',
|
|
default=60,
|
|
# We're using timedelta which can overflow if somebody sets this
|
|
# too high, so limit to a sane value of 10 years.
|
|
max=315576000,
|
|
help=_('Maximum time (in seconds) since the last check-in '
|
|
'of a conductor. A conductor is considered inactive '
|
|
'when this time has been exceeded.')),
|
|
cfg.IntOpt('sync_power_state_interval',
|
|
default=60,
|
|
help=_('Interval between syncing the node power state to the '
|
|
'database, in seconds. Set to 0 to disable syncing.')),
|
|
cfg.IntOpt('check_provision_state_interval',
|
|
default=60,
|
|
min=0,
|
|
help=_('Interval between checks of provision timeouts, '
|
|
'in seconds. Set to 0 to disable checks.')),
|
|
cfg.IntOpt('check_rescue_state_interval',
|
|
default=60,
|
|
min=1,
|
|
help=_('Interval (seconds) between checks of rescue '
|
|
'timeouts.')),
|
|
cfg.IntOpt('check_allocations_interval',
|
|
default=60,
|
|
min=0,
|
|
help=_('Interval between checks of orphaned allocations, '
|
|
'in seconds. Set to 0 to disable checks.')),
|
|
cfg.IntOpt('deploy_callback_timeout',
|
|
default=1800,
|
|
help=_('Timeout (seconds) to wait for a callback from '
|
|
'a deploy ramdisk. Set to 0 to disable timeout.')),
|
|
cfg.BoolOpt('force_power_state_during_sync',
|
|
default=True,
|
|
help=_('During sync_power_state, should the hardware power '
|
|
'state be set to the state recorded in the database '
|
|
'(True) or should the database be updated based on '
|
|
'the hardware state (False).')),
|
|
cfg.IntOpt('power_state_sync_max_retries',
|
|
default=3,
|
|
help=_('During sync_power_state failures, limit the '
|
|
'number of times Ironic should try syncing the '
|
|
'hardware node power state with the node power state '
|
|
'in DB')),
|
|
cfg.IntOpt('sync_power_state_workers',
|
|
default=8, min=1,
|
|
help=_('The maximum number of worker threads that can be '
|
|
'started simultaneously to sync nodes power states from '
|
|
'the periodic task.')),
|
|
cfg.IntOpt('periodic_max_workers',
|
|
default=8,
|
|
help=_('Maximum number of worker threads that can be started '
|
|
'simultaneously by a periodic task. Should be less '
|
|
'than RPC thread pool size.')),
|
|
cfg.IntOpt('node_locked_retry_attempts',
|
|
default=3,
|
|
help=_('Number of attempts to grab a node lock.')),
|
|
cfg.IntOpt('node_locked_retry_interval',
|
|
default=1,
|
|
help=_('Seconds to sleep between node lock attempts.')),
|
|
cfg.BoolOpt('send_sensor_data',
|
|
default=False,
|
|
help=_('Enable sending sensor data message via the '
|
|
'notification bus')),
|
|
cfg.IntOpt('send_sensor_data_interval',
|
|
default=600,
|
|
min=1,
|
|
help=_('Seconds between conductor sending sensor data message '
|
|
'to ceilometer via the notification bus.')),
|
|
cfg.IntOpt('send_sensor_data_workers',
|
|
default=4, min=1,
|
|
help=_('The maximum number of workers that can be started '
|
|
'simultaneously for send data from sensors periodic '
|
|
'task.')),
|
|
cfg.IntOpt('send_sensor_data_wait_timeout',
|
|
default=300,
|
|
help=_('The time in seconds to wait for send sensors data '
|
|
'periodic task to be finished before allowing periodic '
|
|
'call to happen again. Should be less than '
|
|
'send_sensor_data_interval value.')),
|
|
cfg.ListOpt('send_sensor_data_types',
|
|
default=['ALL'],
|
|
help=_('List of comma separated meter types which need to be'
|
|
' sent to Ceilometer. The default value, "ALL", is a '
|
|
'special value meaning send all the sensor data.')),
|
|
cfg.IntOpt('sync_local_state_interval',
|
|
default=180,
|
|
help=_('When conductors join or leave the cluster, existing '
|
|
'conductors may need to update any persistent '
|
|
'local state as nodes are moved around the cluster. '
|
|
'This option controls how often, in seconds, each '
|
|
'conductor will check for nodes that it should '
|
|
'"take over". Set it to 0 (or a negative value) to '
|
|
'disable the check entirely.')),
|
|
cfg.StrOpt('configdrive_swift_container',
|
|
default='ironic_configdrive_container',
|
|
help=_('Name of the Swift container to store config drive '
|
|
'data. Used when configdrive_use_object_store is '
|
|
'True.')),
|
|
cfg.IntOpt('configdrive_swift_temp_url_duration',
|
|
min=60,
|
|
help=_('The timeout (in seconds) after which a configdrive '
|
|
'temporary URL becomes invalid. Defaults to '
|
|
'deploy_callback_timeout if it is set, otherwise to '
|
|
'1800 seconds. Used when '
|
|
'configdrive_use_object_store is True.')),
|
|
cfg.IntOpt('inspect_wait_timeout',
|
|
default=1800,
|
|
help=_('Timeout (seconds) for waiting for node inspection. '
|
|
'0 - unlimited.')),
|
|
cfg.BoolOpt('automated_clean',
|
|
default=True,
|
|
help=_('Enables or disables automated cleaning. Automated '
|
|
'cleaning is a configurable set of steps, '
|
|
'such as erasing disk drives, that are performed on '
|
|
'the node to ensure it is in a baseline state and '
|
|
'ready to be deployed to. This is '
|
|
'done after instance deletion as well as during '
|
|
'the transition from a "manageable" to "available" '
|
|
'state. When enabled, the particular steps '
|
|
'performed to clean a node depend on which driver '
|
|
'that node is managed by; see the individual '
|
|
'driver\'s documentation for details. '
|
|
'NOTE: The introduction of the cleaning operation '
|
|
'causes instance deletion to take significantly '
|
|
'longer. In an environment where all tenants are '
|
|
'trusted (eg, because there is only one tenant), '
|
|
'this option could be safely disabled.')),
|
|
cfg.IntOpt('clean_callback_timeout',
|
|
default=1800,
|
|
help=_('Timeout (seconds) to wait for a callback from the '
|
|
'ramdisk doing the cleaning. If the timeout is reached '
|
|
'the node will be put in the "clean failed" provision '
|
|
'state. Set to 0 to disable timeout.')),
|
|
cfg.IntOpt('rescue_callback_timeout',
|
|
default=1800,
|
|
min=0,
|
|
help=_('Timeout (seconds) to wait for a callback from the '
|
|
'rescue ramdisk. If the timeout is reached the node '
|
|
'will be put in the "rescue failed" provision state. '
|
|
'Set to 0 to disable timeout.')),
|
|
cfg.IntOpt('soft_power_off_timeout',
|
|
default=600,
|
|
min=1,
|
|
help=_('Timeout (in seconds) of soft reboot and soft power '
|
|
'off operation. This value always has to be positive.')),
|
|
cfg.IntOpt('power_state_change_timeout',
|
|
min=2, default=30,
|
|
help=_('Number of seconds to wait for power operations to '
|
|
'complete, i.e., so that a baremetal node is in the '
|
|
'desired power state. If timed out, the power operation '
|
|
'is considered a failure.')),
|
|
cfg.IntOpt('power_failure_recovery_interval',
|
|
min=0, default=300,
|
|
help=_('Interval (in seconds) between checking the power '
|
|
'state for nodes previously put into maintenance mode '
|
|
'due to power synchronization failure. A node is '
|
|
'automatically moved out of maintenance mode once its '
|
|
'power state is retrieved successfully. Set to 0 to '
|
|
'disable this check.')),
|
|
cfg.StrOpt('conductor_group',
|
|
default='',
|
|
help=_('Name of the conductor group to join. Can be up to '
|
|
'255 characters and is case insensitive. This '
|
|
'conductor will only manage nodes with a matching '
|
|
'"conductor_group" field set on the node.')),
|
|
cfg.BoolOpt('allow_deleting_available_nodes',
|
|
default=True,
|
|
mutable=True,
|
|
help=_('Allow deleting nodes which are in state '
|
|
'\'available\'. Defaults to True.')),
|
|
]
|
|
|
|
|
|
def register_opts(conf):
|
|
conf.register_opts(opts, group='conductor')
|