Allow operators to provide a list of disabled boot modes for new deployments ``disallowed_deployment_boot_modes`` and/or enrollments ``disallowed_enrollment_boot_modes``. Defaults are an empty list, [], indicating all modes are allowed. Closes-Bug: #2068530 Change-Id: I1404c81718cd6bb2977e6f298d9b7d11664226d0
437 lines
23 KiB
Python
437 lines
23 KiB
Python
# Copyright 2016 Intel Corporation
|
|
# Copyright 2013 Hewlett-Packard Development Company, L.P.
|
|
# Copyright 2013 International Business Machines Corporation
|
|
# All Rights Reserved.
|
|
#
|
|
# Licensed under the Apache License, Version 2.0 (the "License"); you may
|
|
# not use this file except in compliance with the License. You may obtain
|
|
# a copy of the License at
|
|
#
|
|
# http://www.apache.org/licenses/LICENSE-2.0
|
|
#
|
|
# Unless required by applicable law or agreed to in writing, software
|
|
# distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
|
|
# WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
|
|
# License for the specific language governing permissions and limitations
|
|
# under the License.
|
|
|
|
from oslo_config import cfg
|
|
from oslo_config import types
|
|
|
|
from ironic.common import boot_modes
|
|
from ironic.common.i18n import _
|
|
|
|
|
|
opts = [
|
|
cfg.IntOpt('workers_pool_size',
|
|
default=300, min=3,
|
|
help=_('The size of the workers greenthread pool. '
|
|
'Note that 2 threads will be reserved by the conductor '
|
|
'itself for handling heart beats and periodic tasks. '
|
|
'On top of that, `sync_power_state_workers` will take '
|
|
'up to 7 green threads with the default value of 8.')),
|
|
cfg.IntOpt('reserved_workers_pool_percentage',
|
|
default=5, min=0, max=50,
|
|
help=_('The percentage of the whole workers pool that will be '
|
|
'kept for API requests and other important tasks. '
|
|
'This part of the pool will not be used for periodic '
|
|
'tasks or agent heartbeats. Set to 0 to disable.')),
|
|
cfg.IntOpt('heartbeat_interval',
|
|
default=10,
|
|
help=_('Seconds between conductor heart beats.')),
|
|
cfg.IntOpt('heartbeat_timeout',
|
|
default=60,
|
|
# We're using timedelta which can overflow if somebody sets this
|
|
# too high, so limit to a sane value of 10 years.
|
|
max=315576000,
|
|
mutable=True,
|
|
help=_('Maximum time (in seconds) since the last check-in '
|
|
'of a conductor. A conductor is considered inactive '
|
|
'when this time has been exceeded.')),
|
|
cfg.IntOpt('sync_power_state_interval',
|
|
default=60,
|
|
help=_('Interval between syncing the node power state to the '
|
|
'database, in seconds. Set to 0 to disable syncing.')),
|
|
cfg.IntOpt('check_provision_state_interval',
|
|
default=60,
|
|
min=0,
|
|
help=_('Interval between checks of provision timeouts, '
|
|
'in seconds. Set to 0 to disable checks.')),
|
|
cfg.IntOpt('check_rescue_state_interval',
|
|
default=60,
|
|
min=1,
|
|
help=_('Interval (seconds) between checks of rescue '
|
|
'timeouts.')),
|
|
cfg.IntOpt('check_allocations_interval',
|
|
default=60,
|
|
min=0,
|
|
help=_('Interval between checks of orphaned allocations, '
|
|
'in seconds. Set to 0 to disable checks.')),
|
|
cfg.IntOpt('cache_clean_up_interval',
|
|
default=3600, min=0,
|
|
help=_('Interval between cleaning up image caches, in seconds. '
|
|
'Set to 0 to disable periodic clean-up.')),
|
|
cfg.IntOpt('deploy_callback_timeout',
|
|
default=1800,
|
|
min=0,
|
|
help=_('Timeout (seconds) to wait for a callback from '
|
|
'a deploy ramdisk. Set to 0 to disable timeout.')),
|
|
cfg.BoolOpt('force_power_state_during_sync',
|
|
default=True,
|
|
mutable=True,
|
|
help=_('During sync_power_state, should the hardware power '
|
|
'state be set to the state recorded in the database '
|
|
'(True) or should the database be updated based on '
|
|
'the hardware state (False).')),
|
|
cfg.IntOpt('power_state_sync_max_retries',
|
|
default=3,
|
|
help=_('During sync_power_state failures, limit the '
|
|
'number of times Ironic should try syncing the '
|
|
'hardware node power state with the node power state '
|
|
'in DB')),
|
|
cfg.IntOpt('sync_power_state_workers',
|
|
default=8, min=1,
|
|
help=_('The maximum number of worker threads that can be '
|
|
'started simultaneously to sync nodes power states from '
|
|
'the periodic task.')),
|
|
cfg.IntOpt('periodic_max_workers',
|
|
default=8,
|
|
help=_('Maximum number of worker threads that can be started '
|
|
'simultaneously by a periodic task. Should be less '
|
|
'than RPC thread pool size.')),
|
|
cfg.IntOpt('node_locked_retry_attempts',
|
|
default=3,
|
|
help=_('Number of attempts to grab a node lock.')),
|
|
cfg.IntOpt('node_locked_retry_interval',
|
|
default=1,
|
|
help=_('Seconds to sleep between node lock attempts.')),
|
|
cfg.IntOpt('sync_local_state_interval',
|
|
default=180,
|
|
help=_('When conductors join or leave the cluster, existing '
|
|
'conductors may need to update any persistent '
|
|
'local state as nodes are moved around the cluster. '
|
|
'This option controls how often, in seconds, each '
|
|
'conductor will check for nodes that it should '
|
|
'"take over". Set it to 0 (or a negative value) to '
|
|
'disable the check entirely.')),
|
|
cfg.StrOpt('configdrive_swift_container',
|
|
default='ironic_configdrive_container',
|
|
help=_('Name of the Swift container to store config drive '
|
|
'data. Used when configdrive_use_object_store is '
|
|
'True.')),
|
|
cfg.IntOpt('configdrive_swift_temp_url_duration',
|
|
min=60,
|
|
help=_('The timeout (in seconds) after which a configdrive '
|
|
'temporary URL becomes invalid. Defaults to '
|
|
'deploy_callback_timeout if it is set, otherwise to '
|
|
'1800 seconds. Used when '
|
|
'configdrive_use_object_store is True.')),
|
|
cfg.IntOpt('inspect_wait_timeout',
|
|
default=1800,
|
|
min=0,
|
|
help=_('Timeout (seconds) for waiting for node inspection. '
|
|
'0 - unlimited.')),
|
|
cfg.BoolOpt('automated_clean',
|
|
default=True,
|
|
mutable=True,
|
|
help=_('Enables or disables automated cleaning. Automated '
|
|
'cleaning is a configurable set of steps, '
|
|
'such as erasing disk drives, that are performed on '
|
|
'the node to ensure it is in a baseline state and '
|
|
'ready to be deployed to. This is '
|
|
'done after instance deletion as well as during '
|
|
'the transition from a "manageable" to "available" '
|
|
'state. When enabled, the particular steps '
|
|
'performed to clean a node depend on which driver '
|
|
'that node is managed by; see the individual '
|
|
'driver\'s documentation for details. '
|
|
'NOTE: The introduction of the cleaning operation '
|
|
'causes instance deletion to take significantly '
|
|
'longer. In an environment where all tenants are '
|
|
'trusted (eg, because there is only one tenant), '
|
|
'this option could be safely disabled.')),
|
|
cfg.BoolOpt('allow_provisioning_in_maintenance',
|
|
default=True,
|
|
mutable=True,
|
|
help=_('Whether to allow nodes to enter or undergo deploy or '
|
|
'cleaning when in maintenance mode. If this option is '
|
|
'set to False, and a node enters maintenance during '
|
|
'deploy or cleaning, the process will be aborted '
|
|
'after the next heartbeat. Automated cleaning or '
|
|
'making a node available will also fail. If True '
|
|
'(the default), the process will begin and will pause '
|
|
'after the node starts heartbeating. Moving it from '
|
|
'maintenance will make the process continue.')),
|
|
cfg.IntOpt('clean_callback_timeout',
|
|
default=1800,
|
|
min=0,
|
|
help=_('Timeout (seconds) to wait for a callback from the '
|
|
'ramdisk doing the cleaning. If the timeout is reached '
|
|
'the node will be put in the "clean failed" provision '
|
|
'state. Set to 0 to disable timeout.')),
|
|
cfg.IntOpt('rescue_callback_timeout',
|
|
default=1800,
|
|
min=0,
|
|
help=_('Timeout (seconds) to wait for a callback from the '
|
|
'rescue ramdisk. If the timeout is reached the node '
|
|
'will be put in the "rescue failed" provision state. '
|
|
'Set to 0 to disable timeout.')),
|
|
cfg.IntOpt('soft_power_off_timeout',
|
|
default=600,
|
|
min=1,
|
|
mutable=True,
|
|
help=_('Timeout (in seconds) of soft reboot and soft power '
|
|
'off operation. This value always has to be positive.')),
|
|
cfg.IntOpt('power_state_change_timeout',
|
|
min=2, default=60,
|
|
mutable=True,
|
|
help=_('Number of seconds to wait for power operations to '
|
|
'complete, i.e., so that a baremetal node is in the '
|
|
'desired power state. If timed out, the power operation '
|
|
'is considered a failure.')),
|
|
cfg.IntOpt('power_failure_recovery_interval',
|
|
min=0, default=300,
|
|
help=_('Interval (in seconds) between checking the power '
|
|
'state for nodes previously put into maintenance mode '
|
|
'due to power synchronization failure. A node is '
|
|
'automatically moved out of maintenance mode once its '
|
|
'power state is retrieved successfully. Set to 0 to '
|
|
'disable this check.')),
|
|
cfg.StrOpt('conductor_group',
|
|
default='',
|
|
help=_('Name of the conductor group to join. Can be up to '
|
|
'255 characters and is case insensitive. This '
|
|
'conductor will only manage nodes with a matching '
|
|
'"conductor_group" field set on the node.')),
|
|
cfg.BoolOpt('allow_deleting_available_nodes',
|
|
default=True,
|
|
mutable=True,
|
|
help=_('Allow deleting nodes which are in state '
|
|
'\'available\'. Defaults to True.')),
|
|
cfg.BoolOpt('enable_mdns', default=False,
|
|
help=_('Whether to enable publishing the baremetal API '
|
|
'endpoint via multicast DNS.')),
|
|
cfg.StrOpt('deploy_kernel',
|
|
mutable=True,
|
|
help=_('Glance ID, http:// or file:// URL of the '
|
|
'kernel of the default deploy image.')),
|
|
cfg.StrOpt('deploy_ramdisk',
|
|
mutable=True,
|
|
help=_('Glance ID, http:// or file:// URL of the '
|
|
'initramfs of the default deploy image.')),
|
|
cfg.DictOpt('deploy_kernel_by_arch',
|
|
default={},
|
|
mutable=True,
|
|
help=_('A dictionary of key-value pairs of each architecture '
|
|
'with the Glance ID, http:// or file:// URL of the '
|
|
'kernel of the default deploy image.')),
|
|
cfg.DictOpt('deploy_ramdisk_by_arch',
|
|
default={},
|
|
mutable=True,
|
|
help=_('A dictionary of key-value pairs of each architecture '
|
|
'with the Glance ID, http:// or file:// URL of the '
|
|
'initramfs of the default deploy image.')),
|
|
cfg.StrOpt('rescue_kernel',
|
|
mutable=True,
|
|
help=_('Glance ID, http:// or file:// URL of the '
|
|
'kernel of the default rescue image.')),
|
|
cfg.StrOpt('rescue_ramdisk',
|
|
mutable=True,
|
|
help=_('Glance ID, http:// or file:// URL of the '
|
|
'initramfs of the default rescue image.')),
|
|
cfg.DictOpt('rescue_kernel_by_arch',
|
|
default={},
|
|
mutable=True,
|
|
help=_('A dictionary of key-value pairs of each architecture '
|
|
'with the Glance ID, http:// or file:// URL of the '
|
|
'kernel of the default rescue image.')),
|
|
cfg.DictOpt('rescue_ramdisk_by_arch',
|
|
default={},
|
|
mutable=True,
|
|
help=_('A dictionary of key-value pairs of each architecture '
|
|
'with the Glance ID, http:// or file:// URL of the '
|
|
'initramfs of the default rescue image.')),
|
|
cfg.StrOpt('rescue_password_hash_algorithm',
|
|
default='sha256',
|
|
choices=['sha256', 'sha512'],
|
|
mutable=True,
|
|
help=_('Password hash algorithm to be used for the rescue '
|
|
'password.')),
|
|
cfg.BoolOpt('require_rescue_password_hashed',
|
|
# TODO(TheJulia): Change this to True in Victoria.
|
|
default=False,
|
|
mutable=True,
|
|
help=_('Option to cause the conductor to not fallback to '
|
|
'an un-hashed version of the rescue password, '
|
|
'permitting rescue with older ironic-python-agent '
|
|
'ramdisks.')),
|
|
cfg.StrOpt('bootloader',
|
|
mutable=True,
|
|
help=_('Glance ID, http:// or file:// URL of the EFI system '
|
|
'partition image containing EFI boot loader. This image '
|
|
'will be used by ironic when building UEFI-bootable ISO '
|
|
'out of kernel and ramdisk. Required for UEFI boot from '
|
|
'partition images.')),
|
|
cfg.MultiOpt('clean_step_priority_override',
|
|
item_type=types.Dict(),
|
|
default={},
|
|
help=_('Priority to run automated clean steps for both '
|
|
'in-band and out of band clean steps, provided in '
|
|
'interface.step_name:priority format, e.g. '
|
|
'deploy.erase_devices_metadata:123. The option can '
|
|
'be specified multiple times to define priorities '
|
|
'for multiple steps. If set to 0, this specific step '
|
|
'will not run during cleaning. If unset for an '
|
|
'inband clean step, will use the priority set in the '
|
|
'ramdisk.')),
|
|
cfg.BoolOpt('node_history',
|
|
default=True,
|
|
mutable=True,
|
|
help=_('Boolean value, default True, if node event history '
|
|
'is to be recorded. Errors and other noteworthy '
|
|
'events in relation to a node are journaled to a '
|
|
'database table which incurs some additional load. '
|
|
'A periodic task does periodically remove entries '
|
|
'from the database. Please note, if this is disabled, '
|
|
'the conductor will continue to purge entries as '
|
|
'long as [conductor]node_history_cleanup_batch_count '
|
|
'is not 0.')),
|
|
cfg.IntOpt('node_history_max_entries',
|
|
default=300,
|
|
min=0,
|
|
mutable=True,
|
|
help=_('Maximum number of history entries which will be stored '
|
|
'in the database per node. Default is 300. This setting '
|
|
'excludes the minimum number of days retained using the '
|
|
'[conductor]node_history_minimum_days setting.')),
|
|
cfg.IntOpt('node_history_cleanup_interval',
|
|
min=0,
|
|
default=86400,
|
|
mutable=False,
|
|
help=_('Interval in seconds at which node history entries '
|
|
'can be cleaned up in the database. Setting to 0 '
|
|
'disables the periodic task. Defaults to once a day, '
|
|
'or 86400 seconds.')),
|
|
cfg.IntOpt('node_history_cleanup_batch_count',
|
|
min=0,
|
|
default=1000,
|
|
mutable=False,
|
|
help=_('The target number of node history records to purge '
|
|
'from the database when performing clean-up. '
|
|
'Deletes are performed by node, and a node with excess '
|
|
'records for a node will still be deleted. '
|
|
'Defaults to 1000. Operators who find node history '
|
|
'building up may wish to '
|
|
'lower this threshold and decrease the time between '
|
|
'cleanup operations using the '
|
|
'``node_history_cleanup_interval`` setting.')),
|
|
cfg.IntOpt('node_history_minimum_days',
|
|
min=0,
|
|
default=0,
|
|
mutable=True,
|
|
help=_('The minimum number of days to explicitly keep on '
|
|
'hand in the database history entries for nodes. '
|
|
'This is exclusive from the [conductor]'
|
|
'node_history_max_entries setting as users of '
|
|
'this setting are anticipated to need to retain '
|
|
'history by policy.')),
|
|
cfg.MultiOpt('verify_step_priority_override',
|
|
item_type=types.Dict(),
|
|
default={},
|
|
mutable=True,
|
|
help=_('Priority to run automated verify steps '
|
|
'provided in interface.step_name:priority format,'
|
|
'e.g. management.clear_job_queue:123. The option can '
|
|
'be specified multiple times to define priorities '
|
|
'for multiple steps. If set to 0, this specific step '
|
|
'will not run during verification. ')),
|
|
cfg.BoolOpt('automatic_lessee',
|
|
default=False,
|
|
mutable=True,
|
|
help=_('If the conductor should record the Project ID '
|
|
'indicated by Keystone for a requested deployment. '
|
|
'Allows rights to be granted to directly access the '
|
|
'deployed node as a lessee within the RBAC security '
|
|
'model. The conductor does *not* record this value '
|
|
'otherwise, and this information is not backfilled '
|
|
'for prior instances which have been deployed.')),
|
|
cfg.IntOpt('max_concurrent_deploy',
|
|
default=250,
|
|
min=1,
|
|
mutable=True,
|
|
help=_('The maximum number of concurrent nodes in deployment '
|
|
'which are permitted in this Ironic system. '
|
|
'If this limit is reached, new requests will be '
|
|
'rejected until the number of deployments in progress '
|
|
'is lower than this maximum. As this is a security '
|
|
'mechanism requests are not queued, and this setting '
|
|
'is a global setting applying to all requests this '
|
|
'conductor receives, regardless of access rights. '
|
|
'The concurrent deployment limit cannot be disabled.')),
|
|
cfg.IntOpt('max_concurrent_clean',
|
|
default=50,
|
|
min=1,
|
|
mutable=True,
|
|
help=_('The maximum number of concurrent nodes in cleaning '
|
|
'which are permitted in this Ironic system. '
|
|
'If this limit is reached, new requests will be '
|
|
'rejected until the number of nodes in cleaning '
|
|
'is lower than this maximum. As this is a security '
|
|
'mechanism requests are not queued, and this setting '
|
|
'is a global setting applying to all requests this '
|
|
'conductor receives, regardless of access rights. '
|
|
'The concurrent clean limit cannot be disabled.')),
|
|
cfg.BoolOpt('poweroff_in_cleanfail',
|
|
default=False,
|
|
help=_('If True power off nodes in the ``clean failed`` '
|
|
'state. Default False. Option may be unsafe '
|
|
'when using Cleaning to perform '
|
|
'hardware-transformative actions such as '
|
|
'firmware upgrade.')),
|
|
cfg.BoolOpt('poweroff_in_servicefail',
|
|
default=False,
|
|
help=_('If True power off nodes in the ``service failed`` '
|
|
'state. Default False. Option may be unsafe '
|
|
'when using service to perform '
|
|
'hardware-transformative actions such as '
|
|
'firmware upgrade.')),
|
|
cfg.BoolOpt('permit_child_node_step_async_result',
|
|
default=False,
|
|
mutable=True,
|
|
help=_('This option allows child node steps to not error if '
|
|
'the resulting step execution returned a "wait" '
|
|
'state. Under normal conditions, child nodes are not '
|
|
'expected to request a wait state. This option exists '
|
|
'for operators to use if needed to perform specific '
|
|
'tasks where this is known acceptable. Use at your'
|
|
'own risk!')),
|
|
cfg.IntOpt('max_conductor_wait_step_seconds',
|
|
default=30,
|
|
min=0,
|
|
max=1800,
|
|
mutable=True,
|
|
help=_('The maximum number of seconds which a step can '
|
|
'be requested to explicitly sleep or wait. This '
|
|
'value should be changed sparingly as it holds a '
|
|
'conductor thread and if used across many nodes at '
|
|
'once can exhaust a conductor\'s resources. This'
|
|
'capability has a hard coded maximum wait of 1800 '
|
|
'seconds, or 30 minutes. If you need to wait longer '
|
|
'than the maximum value, we recommend exploring '
|
|
'hold steps.')),
|
|
cfg.ListOpt('disallowed_deployment_boot_modes',
|
|
item_type=types.String(
|
|
choices=[
|
|
(boot_modes.UEFI, _('UEFI boot mode')),
|
|
(boot_modes.LEGACY_BIOS, _('Legacy BIOS boot mode'))],
|
|
),
|
|
default=[],
|
|
mutable=True,
|
|
help=_("Specifies a list of boot modes that are not allowed "
|
|
"during deployment. Eg: ['bios']")),
|
|
]
|
|
|
|
|
|
def register_opts(conf):
|
|
conf.register_opts(opts, group='conductor')
|