
The iSCSI deploy was very easy to start with, but it has since become apparently that it suffers from scalability and maintenance issues. It was deprecated in the Victoria cycle and can now be removed. Hide the guide to upgrade to hardware types since it's very outdated. I had to remove the iBMC diagram since my SVG-fu is not enough to fix it. Change-Id: I2cd6bf7b27fe0be2c08104b0cc37654b506b2e62
136 lines
5.1 KiB
ReStructuredText
136 lines
5.1 KiB
ReStructuredText
Booting a Ramdisk or an ISO
|
|
===========================
|
|
|
|
Ironic supports booting a user provided ramdisk or an ISO image (starting with
|
|
the Victoria release) instead of deploying a node.
|
|
Most commonly this is performed when an instance is booted via PXE, iPXE or
|
|
Virtual Media, with the only local storage contents being those in memory.
|
|
It is suported by ``pxe``, ``ipxe``, ``redfish-virtual-media`` and
|
|
``ilo-virtual-media`` boot interfaces.
|
|
|
|
Configuration
|
|
-------------
|
|
|
|
Ramdisk/ISO boot requires using the ``ramdisk`` deploy interface. As with most
|
|
non-default interfaces, it must be enabled and set for a node to be utilized:
|
|
|
|
.. code-block:: ini
|
|
|
|
[DEFAULT]
|
|
...
|
|
enabled_deploy_interfaces = direct,ramdisk
|
|
...
|
|
|
|
Once enabled and the conductor(s) have been restarted, the interface can
|
|
be set upon creation of a new node:
|
|
|
|
.. code-block:: shell
|
|
|
|
baremetal node create --driver ipmi \
|
|
--deploy-interface ramdisk \
|
|
--boot-interface ipxe
|
|
|
|
or update an existing node:
|
|
|
|
.. code-block:: shell
|
|
|
|
baremetal node set <NODE> --deploy-interface ramdisk
|
|
|
|
You can also use it with :ref:`redfish virtual media
|
|
<redfish-virtual-media-ramdisk>` instead of iPXE.
|
|
|
|
Creating a ramdisk
|
|
------------------
|
|
|
|
A ramdisk can be created using the ``ironic-ramdisk-base`` element from
|
|
ironic-python-agent-builder_, e.g. with Debian:
|
|
|
|
.. code-block:: shell
|
|
|
|
export ELEMENTS_PATH=/opt/stack/ironic-python-agent-builder/dib
|
|
disk-image-create -o /output/ramdisk \
|
|
debian-minimal ironic-ramdisk-base openssh-server dhcp-all-interfaces
|
|
|
|
You should consider using the following elements:
|
|
|
|
* openssh-server_ to install the SSH server since it's not provided by default
|
|
by some minimal images.
|
|
* devuser_ or dynamic-login_ to provide SSH access.
|
|
* dhcp-all-interfaces_ or simple-init_ to configure networking.
|
|
|
|
The resulting files (``/output/ramdisk.kernel`` and
|
|
``/output/ramdisk.initramfs`` in this case) can then be used when `Booting a
|
|
ramdisk`_.
|
|
|
|
Booting a ramdisk
|
|
-----------------
|
|
|
|
Pass the kernel and ramdisk as normally, also providing the ramdisk as an image
|
|
source, for example,
|
|
|
|
.. code-block:: shell
|
|
|
|
baremetal node set <NODE> \
|
|
--instance-info kernel=http://path/to/ramdisk.kernel \
|
|
--instance-info ramdisk=http://path/to/ramdisk.initramfs \
|
|
--instance-info image_source=http://path/to/ramdisk.initramfs
|
|
baremetal node deploy <NODE>
|
|
|
|
.. note::
|
|
The requirement to pass ``image_source`` is artificial and will be fixed
|
|
in a future version of the Bare Metal service.
|
|
|
|
Booting an ISO
|
|
--------------
|
|
|
|
The ``ramdisk`` deploy interface can also be used to boot an ISO image.
|
|
For example,
|
|
|
|
.. code-block:: shell
|
|
|
|
baremetal node set <NODE> \
|
|
--instance-info boot_iso=http://path/to/boot.iso
|
|
baremetal node deploy <NODE>
|
|
|
|
.. warning::
|
|
This feature, when utilized with the ``ipxe`` ``boot_interface``,
|
|
will only allow a kernel and ramdisk to be booted from the
|
|
supplied ISO file. Any additional contents, such as additional
|
|
ramdisk contents or installer package files will be unavailable
|
|
after the boot of the Operating System. Operators wishing to leverage
|
|
this functionality for actions such as OS installation should explore
|
|
use of the standard ``ramdisk`` ``deploy_interface`` along with the
|
|
``instance_info/kernel_append_params`` setting to pass arbitrary
|
|
settings such as a mirror URL for the initial ramdisk to load data from.
|
|
This is a limitation of iPXE and the overall boot process of the
|
|
operating system where memory allocated by iPXE is released.
|
|
|
|
Limitations
|
|
-----------
|
|
|
|
The intended use case is for advanced scientific and ephemeral workloads
|
|
where the step of writing an image to the local storage is not required
|
|
or desired. As such, this interface does come with several caveats:
|
|
|
|
* Configuration drives are not supported with network boot, only with Redfish
|
|
virtual media.
|
|
* Disk image contents are not written to the bare metal node.
|
|
* Users and Operators who intend to leverage this interface should
|
|
expect to leverage a metadata service, custom ramdisk images, or the
|
|
``instance_info/ramdisk_kernel_arguments`` parameter to add options to
|
|
the kernel boot command line.
|
|
* When using PXE/iPXE boot, bare metal nodes must continue to have network
|
|
access to PXE and iPXE network resources. This is contrary to most tenant
|
|
networking enabled configurations where this access is restricted to
|
|
the provisioning and cleaning networks
|
|
* As with all deployment interfaces, automatic cleaning of the node will
|
|
still occur with the contents of any local storage being wiped between
|
|
deployments.
|
|
|
|
.. _ironic-python-agent-builder: https://opendev.org/openstack/ironic-python-agent-builder
|
|
.. _openssh-server: https://docs.openstack.org/diskimage-builder/latest/elements/openssh-server/README.html
|
|
.. _devuser: https://docs.openstack.org/diskimage-builder/latest/elements/devuser/README.html
|
|
.. _dynamic-login: https://docs.openstack.org/diskimage-builder/latest/elements/dynamic-login/README.html
|
|
.. _dhcp-all-interfaces: https://docs.openstack.org/diskimage-builder/latest/elements/dhcp-all-interfaces/README.html
|
|
.. _simple-init: https://docs.openstack.org/diskimage-builder/latest/elements/simple-init/README.html
|