Merge "Dell SC: QOS, Data reduction and fault domain"
This commit is contained in:
commit
c41e999069
@ -123,6 +123,39 @@ To create a volume type that enables replication using Live Volume:
|
||||
$ openstack volume type key --property replication_enabled='<is> True' "ReplicationType"
|
||||
$ openstack volume type key --property replication:livevolume='<is> True' "ReplicationType"
|
||||
|
||||
If QOS options are enabled on the Storage Center they can be enabled via extra
|
||||
specs. The name of the Volume QOS can be specified via the
|
||||
``storagetype:volumeqos`` extra spec. Likewise the name of the Group QOS to
|
||||
use can be specificed via the ``storagetype:groupqos`` extra spec. Volumes
|
||||
created with these extra specs set will be added to the specified QOS groups.
|
||||
|
||||
To create a volume type that sets both Volume and Group QOS:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
$ openstack volume type create "StorageCenterQOS"
|
||||
$ openstack volume type key --property 'storagetype:volumeqos'='unlimited' "StorageCenterQOS"
|
||||
$ openstack volume type key --property 'storagetype:groupqos'='limited' "StorageCenterQOS"
|
||||
|
||||
Data reduction profiles can be specified in the
|
||||
``storagetype:datareductionprofile`` extra spec. Available options are None,
|
||||
Compression, and Deduplication. Note that not all options are available on
|
||||
every Storage Center.
|
||||
|
||||
To create volume types that support no compression, compression, and
|
||||
deduplication and compression respectively:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
$ openstack volume type create "NoCompressionType"
|
||||
$ openstack volume type key --property 'storagetype:datareductionprofile'='None' "NoCompressionType"
|
||||
$ openstack volume type create "CompressedType"
|
||||
$ openstack volume type key --property 'storagetype:datareductionprofile'='Compression' "CompressedType"
|
||||
$ openstack volume type create "DedupType"
|
||||
$ openstack volume type key --property 'storagetype:datareductionprofile'='Deduplication' "DedupType"
|
||||
|
||||
Note: The default is no compression.
|
||||
|
||||
iSCSI configuration
|
||||
~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
@ -298,6 +331,27 @@ Note that this server definition is created once. Changing this setting after
|
||||
the fact will not change an existing definition. The selected Server OS does
|
||||
not have to match the actual OS used on the node.
|
||||
|
||||
Excluding a domain
|
||||
~~~~~~~~~~~~~~~~~~
|
||||
|
||||
This option excludes a Storage Center ISCSI fault domain from the ISCSI
|
||||
properties returned by the initialize_connection call. This only applies to
|
||||
the ISCSI driver.
|
||||
|
||||
Add the excluded_domain_ip option into the backend config for each fault domain
|
||||
to be excluded. This option takes the specified Target IPv4 Address listed
|
||||
under the fault domain. Older versions of DSM (EM) may list this as the Well
|
||||
Known IP Address.
|
||||
|
||||
Add the following to the back-end specification to exclude the domains at
|
||||
172.20.25.15 and 172.20.26.15.
|
||||
|
||||
.. code-block:: ini
|
||||
|
||||
[dell]
|
||||
excluded_domain_ip=172.20.25.15
|
||||
excluded_domain_ip=172.20.26.15
|
||||
|
||||
Driver options
|
||||
~~~~~~~~~~~~~~
|
||||
|
||||
|
Loading…