rajinir 86e7913294 Add support for Dell EMC VNX backend
This change adds a new define for manila::backend::dellemc_vnx,
allowing users to create multiple backend definitions within their puppet
manifests for use with Manila.

Change-Id: I388ed5f9182fe1c595ef992b1aea0f466724916f
Closes-Bug: #1706104
2017-07-24 14:06:25 -05:00

100 lines
3.4 KiB
Puppet

# == define: manila::backend::dellemc_vnx
#
# Configures Manila to use the Dell EMC Isilon share driver
# Compatible for multiple backends
#
# === Parameters
#
# [*driver_handles_share_servers*]
# (required) Denotes whether the driver should handle the responsibility of
# managing share servers. This must be set to false if the driver is to
# operate without managing share servers.
# VMAX driver requires this option to be as True.
#
# [*emc_nas_login*]
# (required) User account name used to access the storage
# system.
#
# [*emc_nas_password*]
# (required) Password for the user account specified in the
# emc_nas_login parameter.
#
# [*emc_nas_server*]
# (required) The hostname (or IP address) for the storage system.
#
# [*emc_share_backend*]
# (required) Share backend.
#
# [*share_backend_name*]
# (optional) Name of the backend in manila.conf that
# these settings will reside in
#
# [*vnx_server_container*]
# (optional) Name of the Data Mover to serve the share service.
# Defaults to None
#
# [*vnx_share_data_pools*]
# (optional) Comma separated list specifying the name of the pools to be
# used by this back end. Do not set this option if all storage pools on the
# system can be used. Wild card character is supported
# Defaults to None
#
# [*vnx_ethernet_ports*]
# (optional) Comma-separated list specifying the ports (devices) of Data Mover
# that can be used for share server interface. Do not set this option if all
# ports on the Data Mover can be used. Wild card character is supported.
# Defaults to None
#
# [*package_ensure*]
# (optional) Ensure state for package. Defaults to 'present'.
#
# === Examples
#
# manila::backend::dellemc_vnx { 'myBackend':
# driver_handles_share_servers => true,
# emc_nas_login => 'admin',
# emc_nas_password => 'password',
# emc_nas_server => <IP address of Unity Syste,>,
# emc_share_backend => 'vnx',
# }
#
define manila::backend::dellemc_vnx (
$driver_handles_share_servers,
$emc_nas_login,
$emc_nas_password,
$emc_nas_server,
$emc_share_backend,
$share_backend_name = $name,
$vnx_server_container = undef,
$vnx_share_data_pools = undef ,
$vnx_ethernet_ports = undef,
$package_ensure = 'present',
) {
include ::manila::deps
validate_string($emc_nas_password)
$vnx_share_driver = 'manila.share.drivers.emc.driver.EMCShareDriver'
manila_config {
"${share_backend_name}/share_driver": value => $vnx_share_driver;
"${share_backend_name}/driver_handles_share_servers": value => $driver_handles_share_servers;
"${share_backend_name}/emc_nas_login": value => $emc_nas_login;
"${share_backend_name}/emc_nas_password": value => $emc_nas_password, secret => true;
"${share_backend_name}/emc_nas_server": value => $emc_nas_server;
"${share_backend_name}/share_backend_name": value => $share_backend_name;
"${share_backend_name}/emc_share_backend": value => $emc_share_backend;
"${share_backend_name}/vnx_server_container": value => $vnx_server_container;
"${share_backend_name}/vnx_share_data_pools": value => $vnx_share_data_pools;
"${share_backend_name}/vnx_ethernet_ports": value => $vnx_ethernet_ports;
}
ensure_resource('package','nfs-utils',{
ensure => $package_ensure,
tag => 'manila-support-package',
})
}