Add new "backend_availability_zone" parameter to every share backend. The parameters are optional, and when set they override the DEFAULT/storage_availability_zone for the corresponding backend. Change-Id: Ie7af8408fe8cec9349593fd9b4cb5bc7deb565cd
139 lines
5.2 KiB
Puppet
139 lines
5.2 KiB
Puppet
# == define: manila::backend::dellemc_vnx
|
|
#
|
|
# Configures Manila to use the Dell EMC Isilon share driver
|
|
# Compatible for multiple backends
|
|
#
|
|
# === Parameters
|
|
#
|
|
# [*emc_nas_login*]
|
|
# (required) User account name used to access the storage
|
|
# system.
|
|
#
|
|
# [*emc_nas_password*]
|
|
# (required) Password for the user account specified in the
|
|
# emc_nas_login parameter.
|
|
#
|
|
# [*emc_nas_server*]
|
|
# (required) The hostname (or IP address) for the storage system.
|
|
#
|
|
# [*emc_share_backend*]
|
|
# (required) Share backend.
|
|
#
|
|
# [*share_backend_name*]
|
|
# (optional) Name of the backend in manila.conf that
|
|
# these settings will reside in
|
|
#
|
|
# [*backend_availability_zone*]
|
|
# (Optional) Availability zone for this share backend.
|
|
# If not set, the storage_availability_zone option value
|
|
# is used as the default for all backends.
|
|
# Defaults to $::os_service_default.
|
|
#
|
|
# [*vnx_server_container*]
|
|
# (optional) Name of the Data Mover to serve the share service.
|
|
# Defaults to $::os_service_default
|
|
#
|
|
# [*vnx_share_data_pools*]
|
|
# (optional) Comma separated list specifying the name of the pools to be
|
|
# used by this back end. Do not set this option if all storage pools on the
|
|
# system can be used. Wild card character is supported
|
|
# Defaults to $::os_service_default
|
|
#
|
|
# [*vnx_ethernet_ports*]
|
|
# (optional) Comma-separated list specifying the ports (devices) of Data Mover
|
|
# that can be used for share server interface. Do not set this option if all
|
|
# ports on the Data Mover can be used. Wild card character is supported.
|
|
# Defaults to $::os_service_default
|
|
#
|
|
# [*network_plugin_ipv6_enabled*]
|
|
# (optional) Whether to support IPv6 network resource, Default=False.
|
|
# If this option is True, both IPv4 and IPv6 are supported.
|
|
# If this option is False, only IPv4 is supported.
|
|
# Defaults to true
|
|
#
|
|
# [*emc_ssl_cert_verify*]
|
|
# (optional) If set to False the https client will not validate the
|
|
# SSL certificate of the backend endpoint.
|
|
# Defaults to false
|
|
#
|
|
# [*emc_ssl_cert_path*]
|
|
# (optional) Can be used to specify a non default path to a
|
|
# CA_BUNDLE file or directory with certificates of trusted
|
|
# CAs, which will be used to validate the backend.
|
|
# Defaults to $::os_service_default
|
|
#
|
|
# [*package_ensure*]
|
|
# (optional) Ensure state for package. Defaults to 'present'.
|
|
#
|
|
# DEPRECATED PARAMETERS
|
|
#
|
|
# [*driver_handles_share_servers*]
|
|
# (optional) Denotes whether the driver should handle the responsibility of
|
|
# managing share servers. This must be set to false if the driver is to
|
|
# operate without managing share servers.
|
|
# VNX driver requires this option to be as True.
|
|
#
|
|
# === Examples
|
|
#
|
|
# manila::backend::dellemc_vnx { 'myBackend':
|
|
# driver_handles_share_servers => true,
|
|
# emc_nas_login => 'admin',
|
|
# emc_nas_password => 'password',
|
|
# emc_nas_server => <IP address of Unity Syste,>,
|
|
# emc_share_backend => 'vnx',
|
|
# }
|
|
#
|
|
define manila::backend::dellemc_vnx (
|
|
$emc_nas_login,
|
|
$emc_nas_password,
|
|
$emc_nas_server,
|
|
$emc_share_backend,
|
|
$share_backend_name = $name,
|
|
$backend_availability_zone = $::os_service_default,
|
|
$vnx_server_container = $::os_service_default,
|
|
$vnx_share_data_pools = $::os_service_default,
|
|
$vnx_ethernet_ports = $::os_service_default,
|
|
$network_plugin_ipv6_enabled = true,
|
|
$emc_ssl_cert_verify = false,
|
|
$emc_ssl_cert_path = $::os_service_default,
|
|
$package_ensure = 'present',
|
|
$driver_handles_share_servers = undef,
|
|
) {
|
|
|
|
include manila::deps
|
|
include manila::params
|
|
|
|
validate_legacy(String, 'validate_string', $emc_nas_password)
|
|
|
|
if $driver_handles_share_servers != undef {
|
|
warning('The driver_handles_share_servers parameter has been deprecated and has no effect')
|
|
}
|
|
|
|
$vnx_share_driver = 'manila.share.drivers.dell_emc.driver.EMCShareDriver'
|
|
|
|
manila_config {
|
|
"${share_backend_name}/share_driver": value => $vnx_share_driver;
|
|
"${share_backend_name}/driver_handles_share_servers": value => true;
|
|
"${share_backend_name}/emc_nas_login": value => $emc_nas_login;
|
|
"${share_backend_name}/emc_nas_password": value => $emc_nas_password, secret => true;
|
|
"${share_backend_name}/emc_nas_server": value => $emc_nas_server;
|
|
"${share_backend_name}/share_backend_name": value => $share_backend_name;
|
|
"${share_backend_name}/backend_availability_zone": value => $backend_availability_zone;
|
|
"${share_backend_name}/emc_share_backend": value => $emc_share_backend;
|
|
"${share_backend_name}/vnx_server_container": value => $vnx_server_container;
|
|
"${share_backend_name}/vnx_share_data_pools": value => $vnx_share_data_pools;
|
|
"${share_backend_name}/vnx_ethernet_ports": value => $vnx_ethernet_ports;
|
|
"${share_backend_name}/network_plugin_ipv6_enabled": value => $network_plugin_ipv6_enabled;
|
|
"${share_backend_name}/emc_ssl_cert_verify": value => $emc_ssl_cert_verify;
|
|
"${share_backend_name}/emc_ssl_cert_path": value => $emc_ssl_cert_path;
|
|
}
|
|
|
|
ensure_packages('nfs-client', {
|
|
name => $::manila::params::nfs_client_package_name,
|
|
ensure => $package_ensure,
|
|
tag => 'manila-support-package',
|
|
})
|
|
|
|
}
|
|
|