Dell server config change to address Redfish image mount failure (pick stx 6.0)
Signed-off-by: Juanita-Balaraj <juanita.balaraj@windriver.com> Change-Id: I4c961007efe448471691f3546d53eacbd7996fce
This commit is contained in:
parent
e7101f76c5
commit
91c5826e41
@ -161,3 +161,24 @@ Executing the dcmanager subcloud reinstall command in the Central Cloud:
|
||||
:start-after: begin-ref-4
|
||||
:end-before: end-ref-4
|
||||
|
||||
.. important::
|
||||
|
||||
**Limitation**: When you perform a touchless subcloud install with Redfish
|
||||
using the :command:`dcmanager subcloud add` command for all servers with
|
||||
iDRAC 9 firmware installed, the subcloud install fails due to an ISO image
|
||||
insertion mount failure over an IPv6 network |prod-dc| system.
|
||||
|
||||
**Workaround**: For all Dell servers with iDRAC 9 firmware installed with
|
||||
version 5.10.00.00 or below, System administrators must perform the
|
||||
following steps:
|
||||
|
||||
.. rubric:: |proc|
|
||||
|
||||
#. Log in to the iDRAC 9 web interface and select, **Configuration \>
|
||||
Virtual Console** from the drop-down menu.
|
||||
|
||||
#. Select **HTML5** (or any other option except eHTML5) from the
|
||||
**Plug-in Type** drop-down menu.
|
||||
|
||||
#. Click **Apply** to apply the change.
|
||||
|
||||
|