@ -161,3 +161,24 @@ Executing the dcmanager subcloud reinstall command in the Central Cloud:
:start-after: begin-ref-4
:end-before: end-ref-4
.. important::
**Limitation**: When you perform a touchless subcloud install with Redfish
using the :command:`dcmanager subcloud add` command for all servers with
iDRAC 9 firmware installed, the subcloud install fails due to an ISO image
insertion mount failure over an IPv6 network |prod-dc| system.
**Workaround**: For all Dell servers with iDRAC 9 firmware installed with
version 5.10.00.00 or below, System administrators must perform the
following steps:
.. rubric:: |proc|
#. Log in to the iDRAC 9 web interface and select, **Configuration \>
Virtual Console** from the drop-down menu.
#. Select **HTML5** (or any other option except eHTML5) from the
**Plug-in Type** drop-down menu.
#. Click **Apply** to apply the change.