.. wjw1596720840345 .. _configure-pci-passthrough-ethernet-interfaces: ============================================= Configure PCI Passthrough Ethernet Interfaces ============================================= A passthrough Ethernet interface is a physical |PCI| Ethernet |NIC| on a compute node to which a virtual machine is granted direct access. This minimizes packet processing delays but at the same time demands special operational considerations. .. rubric:: |context| Configure a |PCI| Passthrough Ethernet Interface on a host and request it for an instance at boot/create time. .. rubric:: |prereq| .. note:: To use |PCI| passthrough or |SRIOV| devices, you must have Intel VT-x and Intel VT-d features enabled in the BIOS. The exercise assumes that the underlying data network **group0-data0** exists already, and that |VLAN| ID 10 is a valid segmentation ID assigned to **project1**. .. rubric:: |proc| #. Log in as the **admin** user to the |prod-p| |prod-hor-long|. #. Lock the compute node you want to configure. #. Configure the Ethernet interface to be used as a PCI passthrough interface. #. Select **Admin** \> **Platform** \> **Host Inventory** from the left-hand pane. #. Select the **Hosts** tab. #. Click the name of the compute host. #. Select the **Interfaces** tab. #. Click the **Edit Interface** button associated with the interface you want to configure. The Edit Interface dialog appears. .. image:: /node_management/figures/ptj1538163621289.png Select **pci-passthrough**, from the **Interface Class** drop-down, and then select the data network to attach the interface. You may also need to change the |MTU|. The interface can also be configured from the |CLI| as illustrated below: .. code-block:: none ~(keystone_admin)$ system host-if-modify -c pci-passthrough compute-0 enp0s3 ~(keystone_admin)$ system interface-datanetwork-assign compute-0 #. Check if the Ethernet interface supports |SRIOV| #. Check the host port associated with the configured |PCI|-passthrough interface. .. code-block:: none ~(keystone_admin)$ system host-if-list | grep pci-passthrough #. Describe the target port to check the value of sriov_totalvfs on it. If the value is None, the Ethernet interface does not support |SRIOV|. Otherwise, it does. .. code-block:: none ~(keystone_admin)$ system host-port-show | grep sriov_totalvfs #. For Ethernet interfaces without |SRIOV| support, there is a known limitation reported `here `__. This limitation is overcome with a specific step later on this procedure. .. note:: It will be required to know if the Ethernet interface supports or not |SRIOV| later in this procedure. #. For Ethernet interfaces that support |SRIOV|, create the **net0** project network .. note:: If the Ethernet interface **DOES NOT** support |SRIOV|, **skip** this step. Log in as the **admin** user to the |os-prod-hor-long|. Select **Admin** \> **Network** \> **Networks**, select the Networks tab, and then click **Create Network**. Fill in the Create Network dialog box as illustrated below. You must ensure that: - **project1** has access to the project network, either assigning it as the owner, as in the illustration (using **Project**), or by enabling the shared flag. - The segmentation ID is set to 10. .. image:: /node_management/figures/bek1516655307871.png Click the **Next** button to proceed to the Subnet tab. Click the **Next** button to proceed to the Subnet Details tab. #. Configure the access switch. Refer to the OEM documentation to configure the access switch. Log in as the **admin** user to the |prod-p| |prod-hor-long|. Configure the physical port on the access switch used to connect to Ethernet interface **enp0s3** as an access port with default |VLAN| ID of 10. Traffic across the connection is therefore untagged, and effectively integrated into the targeted project network. You can also use a trunk port on the access switch so that it handles tagged packets as well. However, this opens the possibility for guest applications to join other project networks using tagged packets with different |VLAN| IDs, which might compromise the security of the system. See |os-intro-doc|: :ref:`L2 Access Switches ` for other details regarding the configuration of the access switch. #. Unlock the compute node. #. For Ethernet interfaces that support |SRIOV|, create a neutron port with a |VNIC| type, direct-physical. .. note:: If the Ethernet interface **DOES NOT** support |SRIOV|, **skip** this step. First, you must set up the environment and determine the correct network |UUID| to use with the port. .. code-block:: none ~(keystone_admin)$ source /etc/platform/openrc ~(keystone_admin)$ OS_AUTH_URL=http://keystone.openstack.svc.cluster.local/v3 ~(keystone_admin)$ openstack network list | grep net0 ~(keystone_admin)$ openstack port create --network --vnic-type direct-physical You have now created a port to be used when launching the server in the next step. #. For Ethernet interfaces that do not support |SRIOV|, the following Nova configuration is required. .. note:: If the Ethernet interface **DOES** support |SRIOV|, **skip** this step. - Get the Ethernet interface ``vendor_id`` and ``product_id``: .. code-block:: none ~(keystone_admin)$ source /etc/platform/openrc ~(keystone_admin)$ system host-port-show | grep -E '(pvendor |pdevice )' - Use the retrieved IDs to create a |PCI| alias with ``"device_type":"type-PCI"``, as peer :ref:`Configure a PCI Alias in Nova `. - Configure a flavor with the extra spec key ``pci_passthrough:alias`` pointing to the previously created |PCI| alias, as peer :ref:`Configure a Flavor to Use a Generic PCI Device ` #. Launch the virtual machine .. note:: You will need to source to the same project selected in the Create Network 'net0' step. - For Ethernet interfaces with |SRIOV| support: specify the port uuid created .. code-block:: none ~(keystone_admin)$ openstack server create --flavor --image --nic port-id= - For Ethernet interfaces without |SRIOV| support: specify the created flavor to use the |PCI| device .. code-block:: none ~(keystone_admin)$ openstack server create --flavor --image For more information, see the Neutron documentation at: `https://docs.openstack.org/neutron/train/admin/config-sriov.html `__. .. rubric:: |result| The new virtual machine instance is up now. It has a PCI passthrough connection to the **net0** project network identified with |VLAN| ID 10. .. only:: partner .. include:: /_includes/configuring-pci-passthrough-ethernet-interfaces.rest :start-after: warning-text-begin :end-before: warning-text-end .. rubric:: |prereq| Access switches must be properly configured to ensure that virtual machines using |PCI|-passthrough or |SRIOV| Ethernet interfaces have the expected connectivity. In a common scenario, the virtual machine using these interfaces connects to external end points only, that is, it does not connect to other virtual machines in the same |prod-os| cluster. In this case: .. _configure-pci-passthrough-ethernet-interfaces-ul-pz2-w4w-rr: - Traffic between the virtual machine and the access switch can be tagged or untagged. - The connecting port on the access switch is part of a port-based |VLAN|. .. only:: partner .. include:: /_includes/configuring-pci-passthrough-ethernet-interfaces.rest :start-after: vlan-bullet-1-begin :end-before: vlan-bullet-1-end - The port-based |VLAN| provides the required connectivity to external switching and routing equipment needed by guest applications to establish connections to the intended end points. For connectivity to other virtual machines in the |prod-os| cluster the following configuration is also required: .. _configure-pci-passthrough-ethernet-interfaces-ul-ngs-nvw-rr: - The |VLAN| ID used for the project network, 10 in this example, and the default port |VLAN| ID of the access port on the switch are the same. This ensures that incoming traffic from the virtual machine is tagged internally by the switch as belonging to |VLAN| ID 10, and switched to the appropriate exit ports. .. only:: partner .. include:: /_includes/configuring-pci-passthrough-ethernet-interfaces.rest :start-after: vlan-bullet-2-begin :end-before: vlan-bullet-2-end .. only:: partner .. include:: /_includes/configuring-pci-passthrough-ethernet-interfaces.rest :start-after: vlan-bullet-3-begin :end-before: vlan-bullet-3-end