docs/doc/source/fault-mgmt/suppressing-an-alarm-using-the-cli.rst
Stone 037c99f0b7 Fault Management doc
Added Data Networks toctree

Changed case on doc title in top level index - changed doc directory to
fault-mgmt.

Added Distributed Cloud section.

Broke out "OpenStack Fault Management Overview" statement about remote log
collection to conditionally included file.

Incorporated patch 6 review comments. Also implemented rST :abbr:
for first instance of SNMP in each file.

Changed port number and community string in two SNMP walk examples.

Change-Id: I1afd71265e752c4c9a54bf2dc9a173b3e17332a7
Signed-off-by: Stone <ronald.stone@windriver.com>
2020-11-27 14:13:00 -05:00

48 lines
1.2 KiB
ReStructuredText

.. ani1552680633324
.. _suppressing-an-alarm-using-the-cli:
===============================
Suppress an Alarm Using the CLI
===============================
You can use the CLI to prevent a monitored system parameter from generating
unnecessary alarms.
.. rubric:: |proc|
#. Use the :command:`fm event-suppress` to suppress a single alarm or
multiple alarms by ID.
.. code-block:: none
~(keystone_admin)$ fm event-suppress [--nowrap] --alarm id <alarm_ id>[,<alarm-id>] \
[--nopaging] [--uuid]
where
**<alarm-id>**
is a comma separated list of alarm UUIDs.
**--nowrap**
disables output wrapping
**--nopaging**
disables paged output
**--uuid**
includes the alarm type UUIDs in the output
An error message is generated in the case of an invalid
<alarm-id>: **Alarm ID not found: <alarm-id\>**.
If the specified number of Alarm IDs is greater than 1, and at least 1 is
wrong, then the suppress command is not applied \(none of the specified
Alarm IDs are suppressed\).
.. note::
Suppressing an Alarm will result in the system NOT notifying the
operator of this particular fault.