800 Series Alarm Messages
The system inventory and maintenance service reports system changes with different degrees of severity. Use the reported alarms to monitor the overall health of the system.
Alarm ID: 800.001 |
Storage Alarm Condition: 1 mons down, quorum 1,2 controller-1,storage-0 |
Entity Instance | cluster=<dist-fs-uuid> |
Degrade Affecting Severity: | None |
Severity: | C/M* |
Proposed Repair Action | If problem persists, contact next level of support. |
Alarm ID: 800.010 | Potential data loss. No available OSDs in storage replication group. |
Entity Instance | cluster=<dist-fs-uuid>.peergroup=<group-x> |
Degrade Affecting Severity: | None |
Severity: | C* |
Proposed Repair Action | Ensure storage hosts from replication group are unlocked and available. Check if OSDs of each storage host are up and running. If problem persists contact next level of support. |
Alarm ID: 800.011 | Loss of replication in peergroup. |
Entity Instance | cluster=<dist-fs-uuid>.peergroup=<group-x> |
Degrade Affecting Severity: | None |
Severity: | M* |
Proposed Repair Action | Ensure storage hosts from replication group are unlocked and available. Check if OSDs of each storage host are up and running. If problem persists contact next level of support. |
Alarm ID: 800.102 |
Storage Alarm Condition: PV configuration <error/failed to apply> on <hostname>. Reason: <detailed reason>. |
Entity Instance | pv=<pv_uuid> |
Degrade Affecting Severity: | None |
Severity: | C/M* |
Proposed Repair Action | Remove failed PV and associated Storage Device then recreate them. |
Alarm ID: 800.103 |
Storage Alarm Condition: [ Metadata usage for LVM thin pool <VG name>/<Pool name> exceeded threshold and automatic extension failed. Metadata usage for LVM thin pool <VG name>/<Pool name> exceeded threshold ]; threshold x%, actual y%. |
Entity Instance | <hostname>.lvmthinpool=<VG name>/<Pool name> |
Degrade Affecting Severity: | None |
Severity: | C* |
Proposed Repair Action | Increase Storage Space Allotment for Cinder on the 'lvm' backend. Consult the user documentation for more details. If problem persists, contact next level of support. |
Alarm ID: 800.104 |
Storage Alarm Condition: <storage-backend-name> configuration failed to apply on host: <host-uuid>. |
Degrade Affecting Severity: | None |
Severity: | C* |
Proposed Repair Action | Update backend setting to reapply configuration. Consult the user documentation for more details. If problem persists, contact next level of support. |