.. uen1559067854074
|
|
.. _creating-network-attachment-definitions:
|
|
|
|
=====================================
|
|
Create Network Attachment Definitions
|
|
=====================================
|
|
|
|
Network attachment definition specifications must be created in order to
|
|
reference / request an |SRIOV| interface in a container specification.
|
|
|
|
.. rubric:: |context|
|
|
|
|
The sample network attachments shown in this procedure can be used in a
|
|
container as shown in :ref:`Using Network Attachment Definitions in a Container
|
|
<using-network-attachment-definitions-in-a-container>`.
|
|
|
|
.. xreflink For information about PCI-SRIOV Interface Support, see the |datanet-doc|:
|
|
:ref:`<data-network-management-data-networks>` guide.
|
|
|
|
.. rubric:: |prereq|
|
|
|
|
You must have configured at least one |SRIOV| interface on a host with the
|
|
target datanetwork \(**datanet-a** or **datanet-b** in the example below\)
|
|
assigned to it before creating a **NetworkAttachmentDefinition** referencing
|
|
this data network.
|
|
|
|
.. note::
|
|
The configuration for this |SRIOV| interface with either a ``netdevice`` or
|
|
``vfio`` vf-driver determines whether the **NetworkAttachmentDefinition**
|
|
will be a kernel network device or a DPDK network device.
|
|
|
|
.. rubric:: |proc|
|
|
|
|
.. _creating-network-attachment-definitions-steps-unordered-tbf-53z-hjb:
|
|
|
|
#. Create a simple |SRIOV| network attachment definition file called net1.yaml
|
|
associated with the data network **datanet-a**.
|
|
|
|
.. code-block:: yaml
|
|
|
|
~(keystone_admin)]$ cat <<EOF > net1.yaml
|
|
apiVersion: "k8s.cni.cncf.io/v1"
|
|
kind: NetworkAttachmentDefinition
|
|
metadata:
|
|
name: net1
|
|
annotations:
|
|
k8s.v1.cni.cncf.io/resourceName: intel.com/pci_sriov_net_datanet_a
|
|
spec:
|
|
config: '{
|
|
"cniVersion": "0.3.0",
|
|
"type": "sriov"
|
|
}'
|
|
EOF
|
|
|
|
|
|
|
|
This **NetworkAttachmentDefinition** is valid for both a kernel-based and
|
|
a DPDK \(vfio\) based device.
|
|
|
|
#. Create an |SRIOV| network attachment.
|
|
|
|
- The following example creates an |SRIOV| network attachment definition
|
|
configured for a VLAN with an ID of 2000.
|
|
|
|
.. code-block:: none
|
|
|
|
~(keystone_admin)]$ cat <<EOF > net2.yaml
|
|
apiVersion: "k8s.cni.cncf.io/v1"
|
|
kind: NetworkAttachmentDefinition
|
|
metadata:
|
|
name: net2
|
|
annotations:
|
|
k8s.v1.cni.cncf.io/resourceName: intel.com/pci_sriov_net_datanet_b
|
|
spec:
|
|
config: '{
|
|
"cniVersion": "0.3.0",
|
|
"type": "sriov",
|
|
"vlan": 2000
|
|
}'
|
|
EOF
|
|
|
|
- The following example creates an |SRIOV| network attachment definition
|
|
configured with IP Address information.
|
|
|
|
.. code-block:: none
|
|
|
|
~(keystone_admin)]$ cat <<EOF > net3.yaml
|
|
apiVersion: crd.projectcalico.org/v1
|
|
kind: IPPool
|
|
metadata:
|
|
name: mypool
|
|
spec:
|
|
cidr: "10.56.219.0/24"
|
|
ipipMode: "Never"
|
|
natOutgoing: True
|
|
---
|
|
apiVersion: "k8s.cni.cncf.io/v1"
|
|
kind: NetworkAttachmentDefinition
|
|
metadata:
|
|
name: net3
|
|
annotations:
|
|
k8s.v1.cni.cncf.io/resourceName: intel.com/pci_sriov_net_datanet_b
|
|
spec:
|
|
config: '{
|
|
"cniVersion": "0.3.0",
|
|
"type": "sriov",
|
|
"ipam": {
|
|
"type": "calico-ipam",
|
|
"assign_ipv4": "true",
|
|
"ipv4_pools": ["mypool"]
|
|
},
|
|
"kubernetes": {
|
|
"kubeconfig": "/etc/cni/net.d/calico-kubeconfig"
|
|
},
|
|
"datastore_type": "kubernetes"
|
|
}'
|
|
EOF
|
|
|
|
|
|
- The following example creates an |SRIOV| network attachment definition
|
|
configured with a static IP address and |MTU| of 1950.
|
|
|
|
.. code-block:: none
|
|
|
|
~(keystone_admin)]$ cat <<EOF > net4.yaml
|
|
apiVersion: k8s.cni.cncf.io/v1
|
|
kind: NetworkAttachmentDefinition
|
|
metadata:
|
|
name: net4
|
|
annotations:
|
|
k8s.v1.cni.cncf.io/resourceName: intel.com/pci_sriov_net_datanet_b
|
|
spec:
|
|
config: '{
|
|
"cniVersion": "0.3.0",
|
|
"plugins":
|
|
[
|
|
{
|
|
"type": "sriov",
|
|
"ipam": {
|
|
"type": "static",
|
|
"addresses": [
|
|
{
|
|
"address": "192.168.1.2/16"
|
|
}
|
|
]
|
|
}
|
|
},
|
|
{
|
|
"type": "tuning",
|
|
"mtu": 1950
|
|
}
|
|
]
|
|
}'
|
|
EOF
|
|
|
|
.. rubric:: |result|
|
|
|
|
After |SRIOV| interfaces have been provisioned and the hosts labeled and
|
|
unlocked, available |SRIOV| VF resources are automatically advertised.
|
|
|
|
They can be referenced in subsequent |prod| operations using the appropriate
|
|
**NetworkAttachmentDefinition** name and the following extended resource name:
|
|
|
|
.. code-block:: none
|
|
|
|
intel.com/pci_sriov_net_${DATANETWORK_NAME}
|
|
|
|
For example, with a network called **datanet-a** the extended resource name
|
|
would be:
|
|
|
|
.. xreflink as shown in |node-doc|:
|
|
:ref:`Provisioning SR-IOV Interfaces using the CLI
|
|
<provisioning-sr-iov-interfaces-using-the-cli>`,
|
|
|
|
.. code-block:: none
|
|
|
|
intel.com/pci_sriov_net_datanet_a
|
|
|
|
.. _creating-network-attachment-definitions-ul-qjr-vnb-xhb:
|
|
|
|
- The extended resource name will convert all dashes \('-'\) in the data
|
|
network name into underscores \('\_'\).
|
|
|
|
- |SRIOV| enabled interfaces using the netdevice VF driver must be
|
|
administratively and operationally up to be advertised by the |SRIOV|
|
|
device plugin.
|
|
|
|
- If multiple data networks are assigned to an interface, the VFs
|
|
resources will be shared between pools.
|
|
|
|
.. seealso::
|
|
|
|
:ref:`Using Network Attachment Definitions in a Container
|
|
<using-network-attachment-definitions-in-a-container>` |