docs/doc/source/usertasks/creating-network-attachment-definitions.rst
Stone f63f0912c6 User Tasks guide
Fixed typo in LetsEncrypt example

Removed duplicate Datanet entry from main index.rst

Reworked Use Kubernetes CPU Manager Static Policy prerequisite block.

Restored fault/index version of FM toctree in top-level index.

Added merged doc entries to top level index.rst.

Incorporated review comments. Also some generic formatting clean-up such as
converting abbreviations to rST-style :abbr: markup.

Moved url with embedded substitution out of code-block.

Addressed patch 2 review comments. Some addtional rST tidying. See comment replies
for open questions/issues.

This patch fixes an issue with 'stx' in filenames that may differ downstream using-an-image-from-the-local-docker-registry-in-a-container-spec
new substitution and changing code-blocks to parsed-literals as required.

Initial submission for review. Note that a couple of references to WR persist
in examples. These will be marked up with comments in the review.

Signed-off-by: Stone <ronald.stone@windriver.com>
Change-Id: I1efef569842caff5def9dc00395b594d91d7a5d0
Signed-off-by: Stone <ronald.stone@windriver.com>
2020-12-02 10:34:53 -05:00

148 lines
4.7 KiB
ReStructuredText

.. uen1559067854074
.. _creating-network-attachment-definitions:
=====================================
Create Network Attachment Definitions
=====================================
Network attachment definition specifications must be created in order to
reference / request an SR-IOV interface in a container specification.
.. rubric:: |context|
The sample network attachments shown in this procedure can be used in a
container as shown in :ref:`Using Network Attachment Definitions in a Container
<using-network-attachment-definitions-in-a-container>`.
.. xreflink For information about PCI-SRIOV Interface Support, see the |datanet-doc|:
:ref:`<data-network-management-data-networks>` guide.
.. rubric:: |prereq|
You must have configured at least one SR-IOV interface on a host with the
target datanetwork \(**datanet-a** or **datanet-b** in the example below\)
assigned to it before creating a **NetworkAttachmentDefinition** referencing
this data network.
.. note::
The configuration for this SR-IOV interface with either a ``netdevice`` or
``vfio`` vf-driver determines whether the **NetworkAttachmentDefinition**
will be a kernel network device or a DPDK network device.
.. rubric:: |proc|
.. _creating-network-attachment-definitions-steps-unordered-tbf-53z-hjb:
#. Create a simple SR-IOV network attachment definition file called net1.yaml
associated with the data network **datanet-a**.
.. code-block:: yaml
~(keystone_admin)$ cat <<EOF > net1.yaml
apiVersion: "k8s.cni.cncf.io/v1"
kind: NetworkAttachmentDefinition
metadata:
name: net1
annotations:
k8s.v1.cni.cncf.io/resourceName: intel.com/pci_sriov_net_datanet_a
spec:
config: '{
"cniVersion": "0.3.0",
"type": "sriov"
}'
EOF
This **NetworkAttachmentDefinition** is valid for both a kernel-based and
a DPDK \(vfio\) based device.
#. Create an SR-IOV network attachment.
- The following example creates an SR-IOV network attachment definition
configured for a VLAN with an ID of 2000.
.. code-block:: none
~(keystone_admin)$ cat <<EOF > net2.yaml
apiVersion: "k8s.cni.cncf.io/v1"
kind: NetworkAttachmentDefinition
metadata:
name: net2
annotations:
k8s.v1.cni.cncf.io/resourceName: intel.com/pci_sriov_net_datanet_b
spec:
config: '{
"cniVersion": "0.3.0",
"type": "sriov",
"vlan": 2000
}'
EOF
- The following example creates an SR-IOV network attachment definition
configured with IP Address information.
.. code-block:: none
~(keystone_admin)$ cat <<EOF > net3.yaml
apiVersion: "k8s.cni.cncf.io/v1"
kind: NetworkAttachmentDefinition
metadata:
name: net3
annotations:
k8s.v1.cni.cncf.io/resourceName: intel.com/pci_sriov_net_datanet_ b
spec:
config: '{
"cniVersion": "0.3.0",
"type": "sriov",
"ipam": {
"type": "host-local"
"subnet": "10.56.219.0/24",
"routes": [{
"dst": "0.0.0.0/0"
}],
"gateway": "10.56.219.1"
}
}'
EOF
.. rubric:: |result|
After SR-IOV interfaces have been provisioned and the hosts labeled and
unlocked, available SR-IOV VF resources are automatically advertised.
They can be referenced in subsequent |prod| operations using the appropriate
**NetworkAttachmentDefinition** name and the following extended resource name:
.. code-block:: none
intel.com/pci_sriov_net_${DATANETWORK_NAME}
For example, with a network called **datanet-a** the extended resource name
would be:
.. xreflink as shown in |node-doc|:
:ref:`Provisioning SR-IOV Interfaces using the CLI
<provisioning-sr-iov-interfaces-using-the-cli>`,
.. code-block:: none
intel.com/pci_sriov_net_datanet_a
.. _creating-network-attachment-definitions-ul-qjr-vnb-xhb:
- The extended resource name will convert all dashes \('-'\) in the data
network name into underscores \('\_'\).
- SR-IOV enabled interfaces using the netdevice VF driver must be
administratively and operationally up to be advertised by the SR-IOV
device plugin.
- If multiple data networks are assigned to an interface, the VFs
resources will be shared between pools.
.. seealso::
:ref:`Using Network Attachment Definitions in a Container